Evidence map›Paper›PMID 29611063›Full record

ArticleLasers in medical science2018

Physical properties of hydrogel wound dressing and its use in low-level laser therapy (LLLT).

K Wachal, E Stachowska, K Korpuścińska, B Nowak, Z Krasiński

Abstract read
PubMed Publisher
In one paragraph

Article in Lasers in medical science, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 9 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

K WachalDepartment of Miniinvasion Surgery, Endomedical Hospital, Chwaliszewo 19a Street, 61-105, Poznan, Poland. krzywach@poczta.fm.
E StachowskaDivision of Metrology and Measurement Systems, Faculty of Mechanical Engineering and Management, Poznan University of Technology, Piotrowo 3, 60-965, Poznan, Poland.
K KorpuścińskaDivision of Metrology and Measurement Systems, Faculty of Mechanical Engineering and Management, Poznan University of Technology, Piotrowo 3, 60-965, Poznan, Poland.
B NowakDivision of Metrology and Measurement Systems, Faculty of Mechanical Engineering and Management, Poznan University of Technology, Piotrowo 3, 60-965, Poznan, Poland.
Z KrasińskiFirst Department and Clinic of General and Vascular Surgery, Poznan University of Medical Sciences, Przemienienia Pańskiego Clinical Hospital, Poznan, Poland.
Poznań University of Technology · PLPoznan University of Medical Sciences · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Hydrogel dressings are routinely used in the treatment of superficial skin wounds. Due to their excellent transparency, we decided to evaluate their usefulness in laser-based medical procedures. We focused on assessing selected physical properties of HydroAid hydrogel wound dressing, used for low-level laser therapy (LLLT) aka laser biostimulation procedures. For the two wavelengths of 660 and 808 nm used in the biostimulation laser POLARIS 2, a dressing transmittance of 92 and 98%, respectively, was determined. Using a FLIR i7 thermal imaging camera, the changes in temperature distribution across the surface of the dressing were assessed, during a 3-h period following its unpacking and placing on the skin of a patient or leaving it at the ambient temperature. The results of the thermal imaging, as well as temperature measurements using a digital thermometer, showed that the cooling properties of a hydrogel dressing were maintained throughout the entire experiment and that it was capable to keep the temperature at least 5° below the skin/ambient (room) temperature. During the 6-h observation using the holographic microscope, which provided indirect insight into the processes occurring within the hydrogel, only minimum topographical changes (observable at a micrometre scale) were recorded, although dressing thickness and its flexibility decreased significantly with time. Additionally, the possibility to regenerate the hydrogel dressing by treating it with distilled water or a physiological salt solution was tested.

Indexed as

BandagesLow-Level Light TherapyWound HealingHumansHydrogelsImaging, Three-DimensionalSkinSkin DiseasesTemperatureWaterHydrogelsWaterHydrogel wound dressingLow-level laser therapyThe holographic microscopeTransmittance

Identifiers

PMID29611063
OpenAlexW2795839786

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.