ArticleThe international journal of cardiovascular imaging2018
Three-dimensional full automated software in the evaluation of the left ventricle function: from theory to clinical practice.
Article in The international journal of cardiovascular imaging, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 13 citations in OpenAlex.
- Comparing HeartModelBMC cardiovascular disorders · 2024Article
- Transcatheter Mitral Valve Intervention: Current and Future Role of Multimodality Imaging for Device Selection and Periprocedural Guidance.Medicina (Kaunas, Lithuania) · 2024Review
- Three-Dimensional Automated, Machine-Learning-Based Left Heart Chamber Metrics: Associations with Prevalent Vascular Risk Factors and Cardiovascular Diseases.Journal of clinical medicine · 2022Article
- Heart ModelInternational journal of general medicine · 2021Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Left ventricular systolic function evaluation is an essential part of all transthoracic echocardiographic (TTE) studies. 3D echocardiography (3DE) is superior to 2D and is recommended as the method of choice. However, since it is time consuming and requires training, it is rarely performed. Different automatic analysis software tries to overcome these limitations but they need to be accurate and reproducible before they can be used clinically. The aim of this study was to test the accuracy and reproducibility of new 3D automatic quantitative software in everyday clinical practice. 69 patients referred to our Echo Lab for a clinically indicated echocardiographic examination were included. All patients underwent a full TTE with 3D image acquisition. Left ventricular volumes and ejection fraction (LVEF) were obtained using Heart Model software, and compared with conventional 3D volumetric data. Automated analysis was performed using three different sliders setting, with or without regional editing if necessary. 20 patients underwent a cardiac magnetic resonance (CMR) study the same day of the echo and automated measurements were also compared with a CMR reference. Intra- and inter-technique comparisons including linear regression with Pearson correlation coefficients and Bland-Altman analyses were calculated. Mean age of the patients was 59 years, with 49.3% male. The automated 3DE model demonstrated excellent correlation with the conventional 3DE measurements of LVEF, using three different sliders settings (r = 0.906; r = 0.898 and r = 0.940). Correlations with CMR values were very good as well (r = 0.888; r = 0.869; r = 0.913). Similarly, no significant differences were noted between the values of EDV and ESV, measured with the automated model or CMR, with excellent correlation (EDV: r = 0.892, r = 0.842, 0.910; ESV: r = 0.925, r = 0.860, r = 0.907). Finally, volumes calculated with the automated software were significantly greater than those obtained manually, but they showed a very good correlation (EDV: r = 0.875, r = 0.856, r = 0.891; ESV: r = 0.929, r = 0.879, r = 949). 3D automatic software for LV quantification is feasible and shows excellent correlations with both CMR and 3D echocardiography, considered the gold standard. No clinically relevant differences were noted when applying different border settings. This technique holds promise to facilitate the integration of 3D TTE into clinical practice.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.