Evidence map›Paper›PMID 29604452›Full record

ArticleNeuroImage2018

MRI gradient-echo phase contrast of the brain at ultra-short TE with off-resonance saturation.

Hongjiang Wei, Peng Cao, Antje Bischof, Roland G Henry, Peder E Z Larson, Chunlei Liu

Abstract read
In one paragraph

Article in NeuroImage, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Quantification of the in vivo brain ultrashort-TMagnetic resonance in medicine · 2024
    Article
  3. Review
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hongjiang WeiDepartment of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA, USA.
Peng CaoRadiology and Biomedical Imaging, UCSF School of Medicine, San Francisco, CA, USA.
Antje BischofDepartment of Neurology, University of California - San Francisco, San Francisco, CA, USA; UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, Berkeley and University of California, San Francisco, CA, USA.
Roland G HenryRadiology and Biomedical Imaging, UCSF School of Medicine, San Francisco, CA, USA.
Peder E Z LarsonRadiology and Biomedical Imaging, UCSF School of Medicine, San Francisco, CA, USA; UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, Berkeley and University of California, San Francisco, CA, USA.
Chunlei LiuDepartment of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA, USA; Helen Wills Neuroscience Institute, University of California, Berkeley, CA, USA. Electronic address: chunlei.liu@berkeley.edu.

Funding

MRI CORTICOGRAPHY: DEVELOPING NEXT GENERATION MICROSCALE HUMAN CORTEX MRI SCANNERU01EB025162 · NIBIB · UNIVERSITY OF CALIFORNIA BERKELEY · PI FEINBERG, DAVID ALAN, LIU, CHUNLEI · 2017 to 2021
$13.4M
Hyperpolarized C-13 Diffusion MRI Measures of Cellular Transport and MetabolismR01EB016741 · NIBIB · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI LARSON, PEDER ERIC ZUFALL · 2014 to 2017
$2.0M
Ultra-Resolution Imaging of Brain Circuitry and its Development in Mental HealthR01MH096979 · NIMH · UNIVERSITY OF CALIFORNIA BERKELEY · PI LIU, CHUNLEI · 2013 to 2017
$1.8M
Novel Ultrashort Echo Time Sequences for Brain MRIR21NS089004 · NINDS · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI LARSON, PEDER ERIC ZUFALL · 2016 to 2017
$436k
NIBIB NIH HHS R01 EB016741NIBIB NIH HHS U01 EB025162NIMH NIH HHS R01 MH096979NINDS NIH HHS R21 NS089004
6 · The paper itself

Abstract

Larmor-frequency shift or image phase measured by gradient-echo sequences has provided a new source of MRI contrast. This contrast is being used to study both the structure and function of the brain. So far, phase images of the brain have been largely obtained at long echo times as maximum phase signal-to-noise ratio (SNR) is achieved at TE = T2* (∼40 ms at 3T). The structures of the brain, however, are compartmentalized and complex with a wide range of signal relaxation times. At such long TE, the short-T2 components are largely attenuated and contribute minimally to phase contrast. The purpose of this study was to determine whether proton gradient-echo images of the brain exhibit phase contrast at ultra-short TE (UTE). Our data showed that UTE images acquired at 7 T without off-resonance saturation do not contain significant phase contrast between gray and white matter. However, UTE images of the brain can attain strong phase contrast even at a nominal TE of 106 μs by using off-resonance RF saturation pulses, which provide direct saturation of ultra-short-T2 components and indirect saturation of longer-T2 components via magnetization transfer. In addition, phase contrast between gray and white matter acquired at UTE with off-resonance saturation is reversed compared to that of the long-T2 signals acquired at long TEs. This finding opens up a potential new way to manipulate image phase contrast of the brain. By accessing short and ultra-short-T2 species, MRI phase images may further improve the characterization of tissue microstructure in the brain.

Indexed as

AdultAgedBrainHumansImage Processing, Computer-AssistedMagnetic Resonance ImagingMultiple SclerosisNeuroimagingBrainMRI – magnetic resonance imagingOff-resonance saturationPhase contrastUTE – ultra-short TE

Identifiers

PMID29604452
PMCPMC5960631

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.