ArticleJournal of clinical laboratory analysis2018
Performance evaluation of a chemiluminescence microparticle immunoassay for CK-MB.
Article in Journal of clinical laboratory analysis, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 8 citations in OpenAlex.
- A Multicenter Validation of a Fully Automated Chemiluminescence Immunoassay for Plasma Elafin in Psoriasis Diagnosis and Severity Assessment.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Article
- Evaluation of the Analytical Performance of a High-Precision Immunoassay for the Creatine Kinase-MB Isoenzyme.Cureus · 2025Article
- Establishment of a new protein C detection system based on chromogenic substrate assay and its clinical diagnostic value for deep vein thrombosis.Journal of clinical laboratory analysis · 2021Article
- Performance evaluation of a chemiluminescence microparticle immunoassay for CK-MB.Journal of clinical laboratory analysis · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 2 institutions in 1 country.
Funding
Abstract
backgroundTo verify and evaluate the performance characteristics of a creatine kinase phosphokinase isoenzymes MB (CK-MB) assay kit, which produced by Xiamen Innodx Biotech Co. Ltd.
methodsEvaluation was carried out according to "Guidelines for principle of analysis performance evaluation of in vitro diagnostic reagent." The performance parameters included detection limit, linearity range, reportable range, recovery test, precision verification, interference test, cross-reactivity, matrix effect, and method comparison.
resultsThe detection limit was 0.1 ng/mL. The assay had clinical linearity over range of 0.1 ng/mL-500 ng/mL. Reportable range was from 0.1 ng/mL to 1000 ng/mL. The average percent of recovery was 99.66%. The coefficient of variation (CV) for within-run and between-run of low CK-MB sample was 5.55% and 6.16%, respectively. As for high-level sample, it was 7.88% and 7.80%. In medical decision level, the relative deviation (Bias) of all interference tests was lower than 15%. When the sample had mild-hemolysis; hemoglobin ≤15 g/L; triglyceride ≤17 mmol/L; bilirubin ≤427.5 μmol/L; rheumatoid factor ≤206U/mL, there was no significant interference to be found. Moreover, assay kit had no cross-reaction with CK-MM and CK-BB. At last, total diagnostic accuracy of kit was 93.24%, when compared with refer kit.
conclusionOverall the results of the verification study indicated the performance of kit is met the requirements of the clinical test.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials