Evidence map›Paper›PMID 29601380›Full record

ArticleClinical orthopaedics and related research2018

Can Genipin-coated Sutures Deliver a Collagen Crosslinking Agent to Improve Suture Pullout in Degenerated Tendon? An Ex Vivo Animal Study.

Roland S Camenzind, Timo O Tondelli, Tobias Götschi, Claude Holenstein, Jess G Snedeker

Open access · greenAbstract read
In one paragraph

Article in Clinical orthopaedics and related research, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.7field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 11 citations in OpenAlex.

  1. Review
  2. A review of current advancements for wound healing: Biomaterial applications and medical devices.Journal of biomedical materials research. Part B, Applied biomaterials · 2022
    Review
  3. Article
  4. Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 4 countries.

Roland S CamenzindR. S. Camenzind, T. O. Tondelli, T. Götschi, C. Holenstein, J. G. Snedeker, Department of Orthopedics, Balgrist University Hospital, Zurich, Switzerland T. Götschi, C. Holenstein, J. G. Snedeker, Institute for Biomechanics, ETH Zurich, Zurich, Switzerland.
Timo O Tondelli
Tobias Götschi
Claude Holenstein
Jess G Snedeker
Herat University · AF

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe suture-tendon interface is often the weakest link in tendon-to-tendon or tendon-to-bone repair. Genipin is an exogenous collagen crosslink agent derived from the gardenia fruit that can enhance suture force to failure of the tendon-suture interface. Viable methods for intraoperative clinical delivery of genipin could be of clinical utility, but to our knowledge have not yet been extensively studied. QUESTIONS/PURPOSES: The purposes of this study were (1) to evaluate whether sutures precoated with genipin can augment the suture-tendon interface to improve force to failure, stiffness, and work to failure in healthy and degenerated tendons; and (2) to determine the effect of genipin on the extent and distribution of crosslinking.

methodsSingle-stitch suture pullout tests were performed ex vivo on 25 bovine superficial digital flexor tendons. To assess effects on native tissue, one group of 12 tendons was cut in proximal and distal halves and randomized to treatment (n = 12) and control groups (n = 12) in a matched-pair design. One simple stitch with a loop with either a normal suture or genipin-coated suture was applied to tendons in both groups. To simulate a degenerative tendon condition, a second group of 13 tendons was cut in proximal and distal halves, injected with 0.2 mL of collagenase D (8 mg/mL) and incubated for 24 hours before suturing with either a genipin-coated suture (n = 13) or their matched controls (n = 13). Sutures from all groups then were loaded to failure on a universal materials testing machine 24 hours after suturing. Suture pullout force, stiffness, and work to failure were calculated from force-displacement data and compared between the groups. Additionally, fluorescence was measured to determine the degree of crosslinking quantitatively and a qualitative analysis of the distribution pattern was performed by microscopy.

resultsIn healthy tendon pairs, the median maximum pullout force was greater with genipin-coated sutures than with control sutures (median, 42 N [range, 24-73 N] versus 29 N [range, 13-48 N]; difference of medians, 13 N; p = 0.003) with corresponding increases in the required work to failure (median, 275 mJ [range, 48-369 mJ] versus 148 mJ [range, 83-369 mJ]; difference of medians, 127 mJ; p = 0.025) but not stiffness (median, 4.1 N/mm [range, 2.3-8.1 N/mm] versus 3.3 N/mm [range, 1.1-9.6 N/mm]; difference of medians, 0.8 N/mm; p = 0.052). In degenerated tendons, median maximum pullout force was greater with genipin-coated sutures than with control sutures (median, 16 N [range, 9-36 N] versus 13 N [range, 5-28 N]; difference of medians, 3 N; p = 0.034) with no differences in work to failure (median, 75 mJ [range, 11-249 mJ] versus 53 mJ [range, 14-143 mJ]; difference of medians, 22 mJ; p = 0.636) or stiffness (median, 1.9 N/mm [range, 0.7-13.4 N/mm] versus 1.6 N/mm [range, 0.5-5.6 N/mm]; difference of medians, 0.3 N/mm; p = 0.285). Fluorescence was higher in tendons treated with genipin-coated sutures compared with the control group, whereas higher fluorescence was observed in the treated healthy compared with the degenerated tendons (difference of means -3.16; standard error 1.08; 95% confidence interval [CI], 0.97-5.34; p = 0.006/healthy genipin: mean 13.04; standard error 0.78; 95% CI, 11.47-14.62; p < 0.001/degenerated genipin: mean 9.88; SD 0.75; 95% CI, 8.34-11.40; p < 0.001).

conclusionsGenipin-coated sutures improved force to failure of a simple stitch at the tendon-suture interface in healthy and degenerated tendons in an ex vivo animal model. Fluorescence was higher in tendons treated with genipin-coated sutures compared with the control group. CLINICAL RELEVANCE: A genipin-coated suture represents a potential delivery vehicle for exogenous crosslink agents to augment suture retention properties. In vivo animal studies are the next logical step to assess safety and efficacy of the approach.

Indexed as

Coated Materials, BiocompatibleSuturesAnimalsCattleCollagenCross-Linking ReagentsEquipment DesignEquipment FailureIn Vitro TechniquesIridoidsMaterials TestingSuture TechniquesTendonsCoated Materials, BiocompatibleCollagenCross-Linking ReagentsgenipinIridoids

Identifiers

PMID29601380
PMCPMC5916599
OpenAlexW2810789992

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.