Interference Assessment of Various Endogenous and Exogenous Substances on the Performance of the Eversense Long-Term Implantable Continuous Glucose Monitoring System.

Carrie Lorenz, Wendolyn Sandoval, Mark Mortellaro

Open access · hybridAbstract read
In one paragraph

Article in Diabetes technology & therapeutics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 36 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
36citing papers in PubMed, 1 pooled it
4.6field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

36 citing papers in PubMed, 1 synthesis or guideline pooled it, 74 citations in OpenAlex.

  1. Guideline
  2. Trial
  3. Article
  4. Article
  5. Review
  6. Review
  7. Inpatient Use of Automated Insulin Delivery Systems.Journal of diabetes science and technology · 2026
    Review
  8. Review
  9. Review
  10. Article
  11. Review
  12. Review
  13. Article
  14. Article
  15. Review
  16. Review
  17. Article
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Carrie LorenzSenseonics, Incorporated , Germantown, Maryland.
Wendolyn SandovalSenseonics, Incorporated , Germantown, Maryland.
Mark MortellaroSenseonics, Incorporated , Germantown, Maryland.
Senseonics (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA variety of prescriptions and over-the-counter medications interfere with transcutaneous continuous glucose monitoring (CGM) sensors. This study characterized the interference profile of the Eversense MATERIALS AND

methodsSensor bias (sensor glucose concentration measurement - plasma glucose concentration measured by a reference test) was measured in vitro against 41 different substances at supratherapeutic/supraphysiologic plasma concentrations. Testing was performed using a paired-sample method adapted from the Clinical and Laboratory Standards Institute guidance document EP7-A2. Any substance producing sensor bias that exceeded the International Organization for Standardization (ISO) document 15197:2013 limits was then tested using an in vitro dose-response method to determine whether the concentration producing a significant sensor bias was within physiologic/therapeutic concentration ranges.

resultsEight of 41 substances produced a sensor bias that exceeded ISO 15197:2013 limits when tested in vitro at supratherapeutic/supraphysiologic plasma concentrations. Only two of these substances (tetracycline and mannitol) exceeded bias limits within therapeutic concentration ranges. Notably, neither acetaminophen nor ascorbic acid, which are substances reported to interfere with other CGM systems, produced sensor bias that exceeded ISO limits when used at physiologic concentrations.

conclusionsAlthough tetracycline and mannitol interfered with the Eversense sensor, substances frequently reported to interfere with enzymatic, electrochemical-based transcutaneous CGM systems, such as acetaminophen and ascorbic acid, did not affect Eversense readings.

Indexed as

AcetaminophenAscorbic AcidBiosensing TechniquesBlood GlucoseBlood Glucose Self-MonitoringHumansMannitolTetracyclineAcetaminophenAscorbic AcidBlood GlucoseMannitolTetracyclineContinuous glucose monitoringDrug interferencesSensor

Identifiers

PMID29600877
PMCPMC5963543
OpenAlexW2795192167

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.