Trial reportAJNR. American journal of neuroradiology2018
An Update on the Adjunctive Neurovascular Support of Wide-Neck Aneurysm Embolization and Reconstruction Trial: 1-Year Safety and Angiographic Results.
Trial report in AJNR. American journal of neuroradiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 2 syntheses or guidelines pooled it, 31 citations in OpenAlex.
- Endoluminal flow diverters in the treatment of sidewall and bifurcation aneurysm: A systematic review and meta-analysis of complications and angiographic outcomes.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2022Pooled it
- Efficacy and safety of PulseRider for treatment of wide-necked intracranial aneurysm-A systematic review and meta-analysis.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2021Pooled it
- Six-month Outcomes after PulseRider- and Conventional Single Stent-assisted Embolization for Bifurcation Aneurysms: A Propensity-adjusted Comparison.Neurologia medico-chirurgica · 2023Article
- Some technical options for successful PulseRider procedures.Surgical neurology international · 2023Article
- Usefulness of Y-shaped PulseRider-assisted coil embolization for basilar artery tip aneurysm with a misaligned axis: A case report.Surgical neurology international · 2023Article
- Enterprise Treatment for Recurrent Basilar Tip Aneurysm after PulseRider-assisted Coil Embolization: A Case Report.NMC case report journal · 2023Article
- Non-contrast-enhanced silent magnetic resonance angiography for assessing cerebral aneurysms after PulseRider treatment.Japanese journal of radiology · 2022Article
- Results of the pToWin Study: Using the pCONUS Device for the Treatment of Wide-Neck Intracranial Aneurysms.Journal of clinical medicine · 2022Article
- Staged Hybrid Techniques With Straightforward Bypass Surgery Followed by Flow Diverter Deployment for Complex Recurrent Middle Cerebral Artery Aneurysms.Frontiers in surgery · 2022Article
- PulseRider Treated Aneurysm with Significant Artifact on Postoperative Magnetic Resonance Angiography: A Case Report and Literature Review.Neurointervention · 2021Article
- Endosurgical Remodeling of Wide-Necked Bifurcation Aneurysms.Frontiers in neurology · 2019Article
- Intracranial Aneurysm: Diagnostic Monitoring, Current Interventional Practices, and Advances.Current treatment options in cardiovascular medicine · 2018Review
- Treatment of wide-necked basilar tip aneurysm not amenable to Y-stenting using the PulseRider device.BMJ case reports · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background and purposeThe safety and efficacy of the PulseRider for the treatment of wide-neck, bifurcation aneurysms at the basilar and carotid terminus locations were studied in a prospective trial, the Adjunctive Neurovascular Support of Wide-Neck Aneurysm Embolization and Reconstruction (ANSWER) trial, reporting on initial 6-month angiographic and clinical results. This report provides insight into the longer term durability and safety with 12-month data. MATERIALS AND
methodsAneurysms treated with the PulseRider among enrolled sites were prospectively studied. Updated 12-month data on clinical and imaging end points are included.
resultsThirty-four patients were enrolled (29 women, 5 men) with a mean age of 60.9 years. The mean aneurysm height ranged from 2.4 to 15.9 mm with a mean neck size of 5.2 mm (range, 2.3-11.6 mm). At 1 year, there were no device migrations or symptomatic in-stent stenoses. Raymond-Roy I occlusion was achieved in 53% of cases at the time of treatment and progressed to 61% and 67% at 6 and 12 months, respectively. Adequate occlusion (Raymond-Roy I/II) progressed from 88% at 6 months to 90% at 12 months. No recanalizations were observed. There was 1 delayed ischemic event. Good outcome (mRS 0-2) was achieved in 90% of patients.
conclusionsThe updated 1-year results from the ANSWER trial demonstrate aneurysm stability and an acceptable safety profile for aneurysms treated at the basilar apex and carotid terminus. Prospective data from a larger set of aneurysms treated at other locations are required to assess how treatment with PulseRider compares with alternatives for treating wide-neck bifurcation aneurysms.