ArticlePloS one2018
Short term evaluation of respiratory effort by premature infants supported with bubble nasal continuous airway pressure using Seattle-PAP and a standard bubble device.
Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 20 citations in OpenAlex.
- Comparison of Ventilator-Derived and Modified Bubble Continuous Positive Airway Pressure for Early Stabilization of Transient Tachypnea of the Newborn: A Retrospective Cohort Study in a Transitional Care Unit.Turkish archives of pediatrics · 2025Article
- Performance Characteristics of a Novel 3D-Printed Bubble Intermittent Mandatory Ventilator (B-IMV) for Adult Pulmonary Support.Bioengineering (Basel, Switzerland) · 2022Article
- Conceptual model of low-cost improvised bubble continuous positive airway pressure device for adults and its potential use in the COVID-19 pandemic.PLoS neglected tropical diseases · 2022Article
- Multichannel esophageal signals to monitor respiratory rate in preterm infants.Pediatric research · 2022Observational
- Maternal and neonatal risk factors for neonatal respiratory distress syndrome in term neonates in Cyprus: a prospective case-control study.Italian journal of pediatrics · 2021Article
- A trial comparing continuous positive airway pressure (CPAP) devices in preterm infants.Journal of perinatology : official journal of the California Perinatal Association · 2020Article
- High amplitude bubble continuous positive airway pressure decreases lung injury in rats with ventilator-induced lung injury.Journal of the Chinese Medical Association : JCMA · 2019Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 5 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAlmost one million prematurely born infants die annually from respiratory insufficiency, predominantly in countries with limited access to respiratory support for neonates. The primary hypothesis tested in the present study was that a modified device for bubble nasal continuous positive airway pressure (Bn-CPAP) would provide lower work of spontaneous breathing, estimated by esophageal pressure-rate products.
methodsInfants born <32 weeks gestation and stable on Bn-CPAP with FiO2 <0.30 were studied within 72 h following delivery. Esophageal pressures during spontaneous breathing were measured during 2 h on standard Bn-CPAP, then 2 h with Bn-CPAP using a modified bubble device presently termed Seattle-PAP, which produces a different pattern of pressure fluctuations and which provided greater respiratory support in preclinical studies, then 2 h on standard Bn-CPAP.
resultsAll 40 infants enrolled completed the study and follow-up through 36 wks post menstrual age or hospital discharge, whichever came first. No infants were on supplemental oxygen at completion of follow-up. No infants developed pneumothoraces or nasal trauma, and no adverse events attributed to the study were observed. Pressure-rate products on the two devices were not different, but effort of breathing, assessed by areas under esophageal pressure-time curves, was lower with Seattle-PAP than with standard Bn-CPAP.
conclusionUse of Seattle-PAP to implement Bn-CPAP lowers the effort of breathing exerted even by relatively healthy spontaneously breathing premature neonates. Whether the lower effort of breathing observed with Seattle-PAP translates to improvements in neonatal mortality or morbidity will need to be determined by studies in appropriate patient populations.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.