Evidence map›Paper›PMID 29580287›Full record

ArticleCardiovascular ultrasound2018

How I do it: feasibility of a new ultrasound probe fixator to facilitate high quality stress echocardiography.

O A E Salden, W M van Everdingen, R Spee, P A Doevendans, M J Cramer

Open access · goldAbstract read
In one paragraph

Article in Cardiovascular ultrasound, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

O A E SaldenDepartment of Cardiology, University Medical Centre Utrecht, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands. o.a.e.salden@umcutrecht.nl.ORCID http://orcid.org/0000-0003-1942-0331
W M van EverdingenDepartment of Cardiology, University Medical Centre Utrecht, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands.
R SpeeDepartment of Cardiology, Maxima Medisch Centrum, Veldhoven, The Netherlands.
P A DoevendansDepartment of Cardiology, University Medical Centre Utrecht, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands.
M J CramerDepartment of Cardiology, University Medical Centre Utrecht, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands.
University Medical Center Utrecht · NLRadboud University Nijmegen · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundStress echocardiography (SE) has recently regained momentum as an important diagnostic tool for the assessment of both ischemic and non-ischemic heart disease. Performing SE during physical exercise is challenging due to a suboptimal patient position and vigorous movements of the patient's chest. This hampers a stable ultrasound position and reduces the diagnostic performance of SE. A stable ultrasound probe position would facilitate producing high quality images during continuous measurements. With Probefix (Usono, Eindhoven, The Netherlands), a newly developed tool to fixate the ultrasound probe to the patient's chest, stabilization of the probe during physical exercise is possible. IMPLEMENTATION AND

resultsThe technique of SE with the Probefix and its' feasibility are evaluated in a small pilot study. Probefix fixates the ultrasound probe to the patient's chest, using two chest straps and a fixation device. The ultrasound probe position and angle may be altered with a relative high degree of freedom. We tested the Probefix for continuous echocardiographic imaging in 12 study subjects during supine and upright ergometer stress tests. One patient was unable to perform exercise and in two study subjects good quality images were not achieved. In the other patients (82%) a stable probe position was obtained, with subsequent good quality echocardiographic images during SE.

conclusionWe have demonstrated the feasibility of the Probefix support during ergometer tests in supine and upright positions and conclude that this external fixator may facilitate continuous monitoring of cardiac function in a group of patients.

Indexed as

AdultAgedAged, 80 and overEchocardiography, StressExercise TestFeasibility StudiesFemaleHealthy VolunteersHeart Valve DiseasesHumansMaleMiddle AgedPilot ProjectsYoung AdultFixationProbeStress echocardiographyUltrasound

Identifiers

PMID29580287
PMCPMC5870734
OpenAlexW2802580989

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.