Evidence map›Paper›PMID 29574547›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2018

Hip capsular thickness correlates with range of motion limitations in femoroacetabular impingement.

Kailai Zhang, Darren de Sa, Hang Yu, Hema Nalini Choudur, Nicole Simunovic, Olufemi Rolland Ayeni

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 1 pooled it
1.9field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 1 synthesis or guideline pooled it, 21 citations in OpenAlex.

  1. The dimensions of the hip capsule can be measured using magnetic resonance imaging and may have a role in arthroscopic planning.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2020
    Pooled it
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Changes in Hip Capsule Morphology after Arthroscopic Treatment for Femoroacetabular Impingement Syndrome with Periportal Capsulotomy are Correlated With Improvements in Patient-Reported Outcomes.Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2022
    Article
  10. Correlation of hip capsule morphology with patient symptoms from femoroacetabular impingement.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2021
    Article
  11. Combining results from hip impingement and range of motion tests can increase diagnostic accuracy in patients with FAI syndrome.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Kailai ZhangMichael G. DeGroote School of Medicine, 1280 Main St W, Hamilton, ON, L8S 4K1, Canada.
Darren de SaUPMC Center for Sports Medicine, 3200 S. Water St, Pittsburgh, PA, 15203, USA.
Hang YuMichael G. DeGroote School of Medicine, 1280 Main St W, Hamilton, ON, L8S 4K1, Canada.
Hema Nalini ChoudurDepartment of Radiology, Hamilton General Hospital, 237 Barton St E, Hamilton, ON, L8L 2X2, Canada.
Nicole SimunovicDivision of Orthopaedic Surgery, Department of Surgery, McMaster University Medical Centre, McMaster University, 1200 Main St West, 4E15, Hamilton, ON, L8N 3Z5, Canada.
Olufemi Rolland AyeniDivision of Orthopaedic Surgery, Department of Surgery, McMaster University Medical Centre, McMaster University, 1200 Main St West, 4E15, Hamilton, ON, L8N 3Z5, Canada. ayenif@mcmaster.ca.
Hamilton Health Sciences · CAMcMaster University Medical Centre · CAHamilton General Hospital · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeFemoroacetabular impingement (FAI) is a clinical entity of the hip causing derangements in range of motion, pain, gait, and function. Computer-assisted modeling and clinical studies suggest that patients with FAI have increased capsular thickness compared to those without.A retrospective chart review was performed to assess relationships between capsular thickness, hip range of motion, and demographic factors in patients with FAI.

methodsLocal Research Ethics Board approval was obtained to extract electronic medical records for 188 patients at a single institution who had undergone hip arthroscopy. Procedures were performed from 2009 to 2017 by a single, fellowship-trained, board-certified sports medicine orthopaedic surgeon. Inclusion criteria were preoperative hip range of motion testing, positive clinical impingement testing, and magnetic resonance imaging (MRI) of the affected hip. Patient demographics, hip range of motion, and time to surgery were recorded. MRIs were reviewed by a board-certified musculoskeletal radiologist blinded to clinical data. Maximum thickness of the anterior hip capsule was measured in axial, axial oblique, and sagittal oblique sequences. Anterior capsular thickness was also measured at the level of the femoral head-neck junction in axial sequences (axial midline).

resultsAxial midline capsular thickness was negatively correlated with hip flexion (r = - 0.196, p = 0.0042) and internal rotation (r = - 0.143, p = 0.0278). Significant differences were seen between genders in axial midline thickness (5.3 ± 1.4 mm males/4.8 ± 1.3 mm females, p = 0.0079), flexion (113° ± 18° males/120° ± 17° females, p = 0.0029), and internal rotation (23° ± 13° males/29° ± 12° females, p = 0.0155). Significant differences also existed between side affected in flexion (116° ± 17° right/119° ± 17° left, p = 0.0396) and internal rotation (26° ± 12° right/29° ± 13° left, p = 0.0029). Positive correlation was observed between axial oblique capsular thickness and flexion (r = 0.2345) (p = 0.0229).

conclusionsIncreased anterior hip capsular thickness at the femoral head-neck correlates with limitations in hip range of motion in FAI. The strength of this relationship may be affected between pathologies, genders, and affected side. Pathologic thickening of the hip capsule may contribute to restricted hip mobility on clinical examination, and elucidation of this relationship may provide guidance into capsular management during hip arthroscopy. LEVEL OF EVIDENCE: 4, retrospective case series.

Indexed as

Range of Motion, ArticularAdolescentAdultAgedArthroscopyChildComputer SimulationFemaleFemoracetabular ImpingementFemur HeadFemur NeckHip JointHumansJoint CapsuleMagnetic Resonance ImagingMaleArthroscopyCapsuleFemoroacetabularHipImpingementMobilityMRISurgery

Identifiers

PMID29574547
OpenAlexW2789394948

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.