Evidence map›Paper›PMID 29572879›Full record

ArticleArtificial organs2018

Patient-Specific Atrial Hemodynamics of a Double Lumen Neonatal Cannula in Correct Caval Position.

Jamil Muhammad, Mohammad Rezaeimoghaddam, Bilgesu Cakmak, Reza Rasooli, Ece Salihoglu, Yahya Yıldız, Kerem Pekkan

Open access · hybridAbstract read
In one paragraph

Article in Artificial organs, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.8field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Impact of altered vena cava flow rates on right atrium flow characteristics.Journal of applied physiology (Bethesda, Md. : 1985) · 2022
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Jamil MuhammadDepartment of Mechanical Engineering, Koç University, Sarıyer, Turkey.ORCID http://orcid.org/0000-0001-7482-5396
Mohammad RezaeimoghaddamDepartment of Mechanical Engineering, Koç University, Sarıyer, Turkey.
Bilgesu CakmakDepartment of Mechanical Engineering, Koç University, Sarıyer, Turkey.
Reza RasooliDepartment of Mechanical Engineering, Koç University, Sarıyer, Turkey.
Ece SalihogluFaculty of Medicine, Department of Cardiovascular Surgery, Istanbul Medipol University, Istanbul, Turkey.
Yahya YıldızDepartment of Anesthesiology and Reanimation, Medipol Mega University Hospital, Istanbul, Turkey.
Kerem PekkanDepartment of Mechanical Engineering, Koç University, Sarıyer, Turkey.ORCID http://orcid.org/0000-0001-7637-4445
Koç University · TRIstanbul Medipol University · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Clinical success of pediatric veno-venous (VV) extracorporeal membrane oxygenation (ECMO) is associated with the double lumen cannula cardiovascular device design as well as its anatomic orientation in the atrium. The positions of cannula ports with respect to the vena cavae and the tricuspid valve are believed to play a significant role on device hemodynamics. Despite various improvements in ECMO catheters, especially for the neonatal and congenital heart patients, it is still challenging to select a catalogue size that would fit to most patients optimally. In effect, the local unfavorable blood flow characteristics of the cannula would translate to an overall loss of efficiency of the ECMO circuit. In this study, the complex flow regime of a neonatal double lumen cannula, positioned in a patient-specific right atrium, is presented for the first time in literature. A pulsatile computational fluid dynamics (CFD) solver that is validated for cardiovascular device flow regimes was used to perform the detailed flow, oxygenated blood transport, and site-specific blood damage analysis using an integrated cannula and right atrium model. A standard 13Fr double lumen cannula was scanned using micro-CT, reconstructed and simulated under physiologic flow conditions. User defined scalar transport equations allowed the quantification of the mixing and convection of oxygenated and deoxygenated blood as well as blood residence times and hemolysis build-up. Site-specific CFD analysis provided key insight into the hemodynamic challenges encountered in cannula design and the associated intra-atrial flow patterns. Due to neonatal flow conditions, an ultra high velocity infusion jet emanated from the infusion port and created a zone of major recirculation in the atrium. This flow regime influenced the delivery of the oxygenated blood to the tricuspid valve. Elevated velocities and complex gradients resulted in higher wall shear stresses (WSS) particularly at the infusion port having the highest value followed by the aspiration hole closest to the drainage port. Our results show that, in a cannula that is perfectly oriented in the atrium, almost 38% of the oxygenated blood is lost to the atrial circulation while only half of the blood from inferior vena cava (IVC) can reach to the tricuspid valve. As such, approximately 6% of venous blood from superior vena cava (SVC) can be delivered to tricuspid. High values of hemolysis index were observed with blood damage encountered around infusion hole (0.025%). These results warrant further improvements in the cannula design to achieve optimal performance of ECMO and better patient outcomes.

Indexed as

Models, CardiovascularCannulaEquipment DesignExtracorporeal Membrane OxygenationHeart AtriaHemodynamicsHumansInfantRegional Blood FlowRespiratory InsufficiencyTricuspid ValveVenae Cavae-Blood residence time-Computational fluid dynamics-Double lumen neonatal cannulaExtracorporeal membrane oxygenation-Hemolysis index

Identifiers

PMID29572879
PMCPMC5947122
OpenAlexW2791730940

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.