Evidence map›Paper›PMID 29566562›Full record

ArticleInternational journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group2018

Transurethral high-intensity ultrasound for treatment of stress urinary incontinence (SUI): simulation studies with patient-specific models.

Dong Liu, Matthew S Adams, E C Burdette, Chris J Diederich

Open access · bronzeAbstract read
In one paragraph

Article in International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Dong Liua Department of Radiation Oncology , University of California San Francisco , San Francisco , CA , USA.
Matthew S Adamsa Department of Radiation Oncology , University of California San Francisco , San Francisco , CA , USA.
E C Burdetteb Acoustic MedSystems Inc. , Savoy , IL , USA.
Chris J Diedericha Department of Radiation Oncology , University of California San Francisco , San Francisco , CA , USA.
University of California, San Francisco · USAcoustic MedSystems (United States) · US

Funding

Image-Guided Transurethral HIFU for Genitourinary TherapyR44DK108458 · NIDDK · ACOUSTIC MEDSYSTEMS, INC. · PI BURDETTE, EVERETTE C, DIEDERICH, CHRIS JOHN · 2015 to 2016
$1.5M
Minimally Invasive High Intensity Ultrasound Treatment of Uterine FibroidsR44CA121740 · NCI · ACOUSTIC MEDSYSTEMS, INC. · PI BURDETTE, EVERETTE C, DIEDERICH, CHRIS JOHN · 2014 to 2015
$1.3M
NCI NIH HHS R44 CA121740NIDDK NIH HHS R44 DK108458
6 · The paper itself

Abstract

backgroundStress urinary incontinence (SUI) is prevalent in adult women, attributed to weakened endopelvic supporting tissues, and typically treated using drugs and invasive surgical procedures. The objective of this in silico study is to explore transurethral high-intensity ultrasound for delivery of precise thermal therapy to the endopelvic tissues adjacent to the mid-urethra, to induce thermal remodeling as a potential minimally invasive treatment alternative.

methods3D acoustic (Rayleigh-Sommerfeld) and biothermal (Pennes bioheat) models of the ultrasound applicator and surrounding tissues were devised. Parametric studies over transducer configuration [frequency, radius-of-curvature (ROC)] and treatment settings (power, duration) were performed, and select cases on patient-specific models were used for further evaluation. Transient temperature and thermal dose distributions were calculated, and temperature and dose metrics reported.

resultsConfigurations using a 5-MHz curvilinear transducer (3.5 × 10 mm, 28 mm ROC) with single 90 s sonication can create heated zones with 11 mm penetration (>50 °C) while sparing the inner 1.8 mm (<45 °C) radial depth of the urethral mucosa. Sequential and discrete applicator rotations can sweep out bilateral coagulation volumes (1.4 W power, 15° rotations, 600 s total time), produce large volumetric (1124 mm³ above 60 EM

conclusionTransurethral applicators with curvilinear ultrasound transducers can deliver spatially selective temperature elevations to lateral mid-urethral targets as a possible means to tighten the endopelvic fascia and adjacent tissues.

Indexed as

Patient-Specific ModelingUltrasonic TherapyFemaleHumansUrethraUrinary Incontinencehigh-intensity ultrasoundstress urinary incontinencetherapeutic ultrasoundthermal ablationThermal therapy

Identifiers

PMID29566562
PMCPMC6136964
OpenAlexW2791705468

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.