ArticleJAMA cardiology2018
Passive Detection of Atrial Fibrillation Using a Commercially Available Smartwatch.
Article in JAMA cardiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 4 registered trials, which are not on this map. Cited by 228 papers, 7 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
FAPO-X: Assisted Digital Telemonitoring With Wearables in Patients After Cardiovascular Surgery
Smartwatches for Detection of Atrial Fibrillation (AFib) in Secondary Prevention of Cryptogenic Stroke - WATCH AFib A Prospective, Intraindividual-controlled, Multicenter Clinical Study
Assessing the Impact of Using the Electrocardiogram Function in Smart Watches on the Level of Anxiety (GAD-7) Among University Students and Employees
I-WEAR: From ICU to Recovery - Evaluating the Feasibility and Usability of Bi-Weekly Health Summaries Using Wearables in Patients After Intensive Care Unit Treatment - A Pilot Study
Who cites it
228 citing papers in PubMed, 7 syntheses or guidelines pooled it, 536 citations in OpenAlex.
- Predicting disease outcomes from remote monitoring using machine learning: a systematic review.BMC medical informatics and decision making · 2026Pooled it
- Prognostic models in populations with heart failure: a systematic review and meta-analysis.Systematic reviews · 2026Pooled it
- Diagnostic accuracy of ECG smart chest patches versus PPG smartwatches for atrial fibrillation detection: a systematic review and meta-analysis.BMC cardiovascular disorders · 2025Pooled it
- 2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines.Journal of the American College of Cardiology · 2024Guideline
- Guideline
- Artificial Intelligence for Detection of Cardiovascular-Related Diseases from Wearable Devices: A Systematic Review and Meta-Analysis.Yonsei medical journal · 2022Pooled it
- Diagnostic Accuracy of Smartwatches for the Detection of Cardiac Arrhythmia: Systematic Review and Meta-analysis.Journal of medical Internet research · 2021Pooled it
- 2-Hydroxybenzylamine for Treatment of Atrial Fibrillation: A First-in-Human Clinical Pilot Trial.Circulation. Arrhythmia and electrophysiology · 2025Trial
- Development and validation of a machine learning model for diagnosis of ischemic heart disease using single-lead electrocardiogram parameters.World journal of cardiology · 2025Trial
- Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation.The New England journal of medicine · 2019Trial
- Application of Artificial Intelligence and Machine Learning in Arrhythmia Detection and Pacemaker Data Analysis.Cardiology research · 2026Review
- Artificial Intelligence Enabled Diagnostics Using Photoplethysmography (PPG): Beyond SpOLife (Basel, Switzerland) · 2026Review
- Wearable Devices in Cardiovascular Care: A Narrative Review of the Transition Toward Predictive, Preventive, Personalized, and Participatory Medicine.Healthcare (Basel, Switzerland) · 2026Review
- Wearable smartwatches for atrial fibrillation detection and burden estimation after ablation: comparison with continuous monitoring.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026Article
- AI-Driven Atrial Fibrillation Management: From Signal to Strategy.Balkan medical journal · 2026Review
- Artificial intelligence and the evolution of the electrocardiogram: from cardiovascular diagnostic tool to digital biomarker.European heart journal. Digital health · 2026Review
- Estimating time of death from smartwatch data: initial empirical results.Scientific reports · 2026Article
- Review
- Comparative analysis of 6-lead and single-lead consumer-grade electrocardiograms: diagnostic accuracy, numerical agreement, and inter-rater reliability.European heart journal. Digital health · 2026Article
- A systematic evaluation of uncertainty quantification techniques in deep learning: a case study in photoplethysmography signal analysis.Machine learning. Health · 2026Article
168 more citing papers are in PubMed but not listed here.
Corrections and comments
- Commented on by
Authors and funding
14 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Importance: Atrial fibrillation (AF) affects 34 million people worldwide and is a leading cause of stroke. A readily accessible means to continuously monitor for AF could prevent large numbers of strokes and death. Objective: To develop and validate a deep neural network to detect AF using smartwatch data. Design, Setting, and Participants: In this multinational cardiovascular remote cohort study coordinated at the University of California, San Francisco, smartwatches were used to obtain heart rate and step count data for algorithm development. A total of 9750 participants enrolled in the Health eHeart Study and 51 patients undergoing cardioversion at the University of California, San Francisco, were enrolled between February 2016 and March 2017. A deep neural network was trained using a method called heuristic pretraining in which the network approximated representations of the R-R interval (ie, time between heartbeats) without manual labeling of training data. Validation was performed against the reference standard 12-lead electrocardiography (ECG) in a separate cohort of patients undergoing cardioversion. A second exploratory validation was performed using smartwatch data from ambulatory individuals against the reference standard of self-reported history of persistent AF. Data were analyzed from March 2017 to September 2017. Main Outcomes and Measures: The sensitivity, specificity, and receiver operating characteristic C statistic for the algorithm to detect AF were generated based on the reference standard of 12-lead ECG-diagnosed AF. Results: Of the 9750 participants enrolled in the remote cohort, including 347 participants with AF, 6143 (63.0%) were male, and the mean (SD) age was 42 (12) years. There were more than 139 million heart rate measurements on which the deep neural network was trained. The deep neural network exhibited a C statistic of 0.97 (95% CI, 0.94-1.00; P < .001) to detect AF against the reference standard 12-lead ECG-diagnosed AF in the external validation cohort of 51 patients undergoing cardioversion; sensitivity was 98.0% and specificity was 90.2%. In an exploratory analysis relying on self-report of persistent AF in ambulatory participants, the C statistic was 0.72 (95% CI, 0.64-0.78); sensitivity was 67.7% and specificity was 67.6%. Conclusions and Relevance: This proof-of-concept study found that smartwatch photoplethysmography coupled with a deep neural network can passively detect AF but with some loss of sensitivity and specificity against a criterion-standard ECG. Further studies will help identify the optimal role for smartwatch-guided rhythm assessment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.