Observational studyJournal of clinical monitoring and computing2019
Continuous noninvasive arterial blood pressure monitoring using the vascular unloading technology during complex gastrointestinal endoscopy: a prospective observational study.
Observational study in Journal of clinical monitoring and computing, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 14 citations in OpenAlex.
- Orthostatic-dependent cardiopulmonary responses among trained females during intensity matched resistance exercises in a pilot randomized crossover study.Scientific reports · 2025Trial
- Effect of Remimazolam versus Propofol on Hemodynamics in Elderly Hypertensive Patients Undergoing Gastroenteroscopy: A Multicenter, Randomized Controlled Clinical Trial.Drug design, development and therapy · 2025Trial
- Management of gastrointestinal bleed in the intensive care setting, an updated literature review.World journal of critical care medicine · 2025Review
- Predictors of sepsis, intensive care unit admission, and death in patients hospitalized for complicated skin and soft tissue infections: Retrospective study at a large tertiary-care center.SAGE open medicine · 2025Article
- Patent landscape review of non-invasive medical sensors for continuous monitoring of blood pressure and their validation in critical care practice.Frontiers in medicine · 2023Review
- Wearable skin-like optoelectronic systems with suppression of motion artifacts for cuff-less continuous blood pressure monitor.National science review · 2020Article
- Journal of Clinical Monitoring and Computing end of year summary 2019: hemodynamic monitoring and management.Journal of clinical monitoring and computing · 2020Review
- [Principles and pitfalls of arterial blood pressure measurement].Der Anaesthesist · 2019Article
- [Anesthesia in gastrointestinal endoscopy: peroral endoscopic myotomy].Der Anaesthesist · 2019Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The innovative vascular unloading technology (VUT) allows continuous noninvasive arterial blood pressure (AP) monitoring. We aimed to investigate whether the VUT enables AP changes to be detected earlier compared with intermittent AP monitoring in patients undergoing gastrointestinal endoscopy. In this prospective observational study, we recorded continuous AP measurements with the VUT (CNAP system; CNSystems Medizintechnik AG, Graz, Austria) and intermittent AP measurements with upper arm cuff oscillometry in 90 patients undergoing complex gastrointestinal endoscopy (Department of Interventional Endoscopy at the University Medical Center Hamburg-Eppendorf, Hamburg, Germany). A "hypotensive phase" was defined as a time period of at least 30 s during which ≥ 50% of the VUT-AP values were in a predefined range of hypotension, i.e., AP value a) ≥ 10% below the last oscillometric value and b) ≤ 65 mmHg for mean AP or ≤ 90 mmHg for systolic AP. In the 5-min-interval between two oscillometric measurements, one or more hypotensive phases were detected in 26 patients (29%) for mean AP and in 27 patients (30%) for systolic AP. Hypotensive phases had a mean duration of 195 ± 99 s for mean AP and 197 ± 97 s for systolic AP with a mean procedure duration of 36 (± 21) min. Continuous noninvasive AP monitoring using the VUT enables hypotensive phases to be detected earlier compared with intermittent AP monitoring during complex gastrointestinal endoscopy. These hypotensive phases may be missed or only belatedly recognized with intermittent AP monitoring. Continuous noninvasive AP measurement facilitates detecting hemodynamic instability more rapidly and therefore may improve patient safety.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.