Evidence map›Paper›PMID 29552402›Full record

ArticleBiomedical optics express2018

Large area laser scanning optical resolution photoacoustic microscopy using a fibre optic sensor.

Thomas J Allen, Olumide Ogunlade, Edward Zhang, Paul C Beard

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
2.8field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 42 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Photoacoustic imaging aided with deep learning: a review.Biomedical engineering letters · 2022
    Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Review
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Thomas J AllenDepartment of Medical Physics and Biomedical Engineering, University College London, Gower Street, WC1E6BT, UK.
Olumide OgunladeDepartment of Medical Physics and Biomedical Engineering, University College London, Gower Street, WC1E6BT, UK.
Edward ZhangDepartment of Medical Physics and Biomedical Engineering, University College London, Gower Street, WC1E6BT, UK.
Paul C BeardDepartment of Medical Physics and Biomedical Engineering, University College London, Gower Street, WC1E6BT, UK.
University College London · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A laser scanning optical resolution photoacoustic microscopy (LS OR-PAM) system based on a stationary fibre optic sensor is described. The sensor comprises an optically resonant interferometric polymer cavity formed on the tip of a rounded single mode optical fibre. It provides low noise equivalent pressure (NEP = 68.7 Pa over a 20 MHz measurement bandwidth), a broad bandwidth that extends to 80 MHz and a near omnidirectional response. The latter is a significant advantage, as it allows large areas (>1cm

Indexed as

(110.5120) Photoacoustic imaging(170.3880) Medical and biological imaging

Identifiers

PMID29552402
PMCPMC5854068
OpenAlexW2784183727

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.