Evidence map›Paper›PMID 29552394›Full record

ArticleBiomedical optics express2018

Diffuse optical monitoring of peripheral tissues during uncontrolled internal hemorrhage in a porcine model.

Karthik Vishwanath, Rajan Gurjar, David Wolf, Suzannah Riccardi, Michael Duggan, David King

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Karthik VishwanathDepartment of Physics, Miami University, Oxford, OH 45056, USA.
Rajan GurjarMIT Lincoln Laboratory, 244 Wood Street, Lexington, MA 02420, USA.
David WolfWarner Babcock Institute for Green Chemistry, 100 Research Drive, Wilmington, MA 01887, USA.
Suzannah RiccardiMIT Lincoln Laboratory, 244 Wood Street, Lexington, MA 02420, USA.
Michael DugganDivision of Trauma, Emergency Surgery, and Surgical Critical Care, Massachusetts General Hospital, 165 Cambridge Street, Suite 810 Boston, MA 02114, USA.
David KingDivision of Trauma, Emergency Surgery, and Surgical Critical Care, Massachusetts General Hospital, 165 Cambridge Street, Suite 810 Boston, MA 02114, USA.
Radiation Monitoring Devices (United States) · USMassachusetts General Hospital · US

Funding

Can Optical Spectroscopy Predict Early Treatment Response in Solid TumorsR00CA140783 · NCI · RADIATION MONITORING DEVICES, INC. · PI VISHWANATH, KARTHIK · 2012 to 2014
$611k
NCI NIH HHS R00 CA140783
6 · The paper itself

Abstract

Reliable, continuous and noninvasive blood flow and hemoglobin monitoring in trauma patients remains a critical, but generally unachieved goal. Two optical sensing methods - diffuse correlation spectroscopy (DCS) and diffuse reflectance spectroscopy (DRS) - are used to monitor and detect internal hemorrhage. Specifically, we investigate if cutaneous perfusion measurements acquired using DCS and DRS in peripheral (thighs and ear-lobe) tissues could detect severe hemorrhagic shock in a porcine model. Four animals underwent high-grade hepato-portal injury in a closed abdomen, to induce uncontrolled hemorrhage and were subsequently allowed to bleed for 10 minutes before fluid resuscitation. DRS and DCS measurements of cutaneous blood flow were acquired using fiber optical probes placed on the thigh and earlobe of the animals and were obtained repeatedly starting from 1 to 5 minutes pre-injury, up to several minutes post shock. Clear changes were observed in measured optical spectra across all animals at both sites. DCS-derived cutaneous blood flow decreased sharply during hemorrhage, while DRS-derived vascular saturation and hemoglobin paralleled cardiac output. All derived optical parameters had the steepest changes during the rapid initial hemorrhage unambiguously. This suggests that a combined DCS and DRS based device might provide an easy-to-use, non-invasive, internal-hemorrhage detection system that can be used across a wide array of clinical settings.

Indexed as

(000.1430) Biology and medicine(170.1610) Clinical applications(170.3660) Light propagation in tissues(170.6480) Spectroscopy, speckle(170.6510) Spectroscopy, tissue diagnostics

Identifiers

PMID29552394
PMCPMC5854059
OpenAlexW2782844610

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.