Evidence map›Paper›PMID 29548292›Full record

ArticleBiomedical engineering online2018

Influence of injection rates of calibrating standard solution on monitoring pulse indicator continuous cardiac output.

Chen Shu-Lan, Lan Fang-Chen, Du Zhen-Shuang, Xu Ya-Ping, Zhao Hui-Ming, Zeng Cui-Ping, Miao Yu

Open access · goldAbstract read
In one paragraph

Article in Biomedical engineering online, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact, top 91% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it, 0 citations in OpenAlex.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Chen Shu-LanGeneral Surgery Department, The 180th Hospital of Chinese People's Liberation Army, Quanzhou, 362000, Fujian, China.
Lan Fang-ChenGeneral Surgery Department, The 180th Hospital of Chinese People's Liberation Army, Quanzhou, 362000, Fujian, China.
Du Zhen-ShuangGeneral Surgery Department, The 180th Hospital of Chinese People's Liberation Army, Quanzhou, 362000, Fujian, China.
Xu Ya-PingGeneral Surgery Department, The 180th Hospital of Chinese People's Liberation Army, Quanzhou, 362000, Fujian, China.
Zhao Hui-MingGeneral Surgery Department, The 180th Hospital of Chinese People's Liberation Army, Quanzhou, 362000, Fujian, China.
Zeng Cui-PingGeneral Surgery Department, The 180th Hospital of Chinese People's Liberation Army, Quanzhou, 362000, Fujian, China.
Miao YuGeneral Surgery Department, The 180th Hospital of Chinese People's Liberation Army, Quanzhou, 362000, Fujian, China. 735854218@qq.com.
Chinese People's Liberation Army · CNThe 180th Hospital of PLA · CN

Funding

Science and Technology Achievements Promotion Project 2011Z32
6 · The paper itself

Abstract

objectiveThis study aimed to investigate the influence of injection rates of calibrating standard solution on monitoring pulse indicator continuous cardiac output (PICCO, made in Germany), and thereby to provide significant references for clinical practice.

methodsA total of 108 critical patients in stroke intensive care unit were identified. All these participants received transesophageal cardiac color Doppler ultrasound, and within 15 min PICCO equipment was utilized to monitor the relevant parameters, by means of 0 °C calibrating standard solution, and the injection speeds were 2-4, 5-7, and 8-10 s. Besides, the monitoring indicators were as follows, cardiac index, global ejection fraction, global end diastolic volume index. The potential correlations were evaluated between PICCO and transesophageal cardiac color Doppler ultrasound.

resultsAll the data was available, and the monitored parameters of PICOO at 2-4, 5-7, and 8-10 s were positively correlated with the parameters obtained from transesophageal cardiac color Doppler ultrasound (P < 0.05). Specially, it is worth emphasizing that the best correlation between them could be provided when the injection rate was 2-4 s.

conclusionWhen the injection rate at 2-4 s, the parameters obtained by PICOO were much closer to that of transesophageal cardiac color Doppler ultrasound. Furthermore, the parameters of PICOO obtained at 2-4 s could better reflect cardiac function of patients.

Indexed as

Cardiac OutputAdolescentAdultAgedCalibrationFemaleHumansInjectionsIntensive Care UnitsMaleMiddle AgedMonitoring, PhysiologicSolutionsStrokeYoung AdultSolutionsCalibrating standard solutionInjection ratePulse indicator continuous cardiac output

Identifiers

PMID29548292
PMCPMC5857084
OpenAlexW2802624982

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.