Evidence map›Paper›PMID 29542112›Full record

SynthesisThe Cochrane database of systematic reviews2018

Laryngeal mask airway versus bag-mask ventilation or endotracheal intubation for neonatal resuscitation.

Mosarrat J Qureshi, Manoj Kumar

Open access · hybridAbstract readComparative StudyMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 33 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
33citing papers in PubMed, 4 pooled it
13.2field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

33 citing papers in PubMed, 4 syntheses or guidelines pooled it, 93 citations in OpenAlex.

  1. Guideline
  2. Pooled it
  3. Pooled it
  4. Guideline
  5. Trial
  6. Rapid Airway Placement Without Pausing Chest Compressions: Supraglottic Airway Versus Endotracheal Intubation.Pediatrics international : official journal of the Japan Pediatric Society
    Trial
  7. Article
  8. Review
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. [Update 2022: interdisciplinary statement on airway management with supraglottic airway devices in pediatric emergency medicine-The laryngeal mask is and remains state of the art : Joint statement of the Institute for Emergency Medicine and Medicine Management (INM), the University Clinic Munich, LMU Munich, Germany, the Working Group for Pediatric Critical Care and Emergency Medicine of the German Interdisciplinary Society for Critical Care and Emergency Medicine (DIVI), the Medical Directors of Emergency Medical Services in Bavaria (ÄLRD), the Scientific Working Group for Pediatric Anesthesia (WAKKA) of the German Society for Anesthesiology and Intensive Care Medicine (DGAI), the Scientific Working Group for Emergency Medicine of the German Society for Anesthesiology and Intensive Care Medicine (DGAI) and the Society of Neonatology and Pediatric Critical Care Medicine (GNPI)].Die Anaesthesiologie · 2023
    Review
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 1 country.

Mosarrat J QureshiNorthern Alberta Neonatal Program, Royal Alexandra Hospital, 10240 Kingsway Avenue, Edmonton, AB, Canada, T5H 3V9.
Manoj Kumar
Royal Alexandra Hospital · CAUniversity of Alberta · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundProviding effective positive pressure ventilation is considered to be the single most important component of successful neonatal resuscitation. Ventilation is frequently initiated manually with bag and face mask (BMV) followed by endotracheal intubation if respiratory depression continues. These techniques may be difficult to perform successfully resulting in prolonged resuscitation or neonatal asphyxia. The laryngeal mask airway (LMA) may achieve initial ventilation and successful resuscitation faster than a bag-mask device or endotracheal intubation.

objectivesAmong newborns requiring positive pressure ventilation for cardio-pulmonary resuscitation, is LMA more effective than BMV or endotracheal intubation for successful resuscitation? When BMV is either insufficient or ineffective, is effective positive pressure ventilation and successful resuscitation achieved faster with the LMA compared to endotracheal intubation? SEARCH

methodsWe used the standard search strategy of Cochrane Neonatal to search the Cochrane Central Register of Controlled Trials (CENTRAL 2017, Issue 1), MEDLINE via PubMed (1966 to 15 February 2017), Embase (1980 to 15 February 2017), and CINAHL (1982 to 15 February 2017). We also searched clinical trials registers, conference proceedings, and the reference lists of retrieved articles for randomised controlled trials and quasi-randomised trials. SELECTION CRITERIA: We included randomised and quasi-randomised controlled trials that compared LMA for neonatal resuscitation with either BMV or endotracheal intubation and reported on any outcomes related to neonatal resuscitation specified in this review. DATA COLLECTION AND ANALYSIS: Two review authors independently evaluated studies for risk of bias assessments, and extracted data using Cochrane Neonatal criteria. Categorical treatment effects were described as relative risks and continuous treatment effects were described as the mean difference, with 95% confidence intervals (95% CI) of estimates. MAIN

resultsWe included seven trials that involved a total of 794 infants. Five studies compared LMA with BMV and three studies compared LMA with endotracheal intubation. We added six new studies for this update (754 infants).LMA was associated with less need for endotracheal intubation than BMV (typical risk ratio (RR) 0.24, 95% CI 0.12 to 0.47 and typical risk difference (RD) -0.14, 95% CI -0.14 to -0.06; 5 studies, 661 infants; moderate-quality evidence) and shorter ventilation time (mean difference (MD) -18.90 seconds, 95% CI -24.35 to -13.44; 4 studies, 610 infants). Babies resuscitated with LMA were less likely to require admission to neonatal intensive care unit (NICU) (typical RR 0.60, 95% CI 0.40 to 0.90 and typical RD -0.18, 95% CI -0.31 to -0.04; 2 studies,191 infants; moderate-quality evidence). There was no difference in deaths or hypoxic ischaemic encephalopathy (HIE) events.Compared to endotracheal intubation, there were no clinically significant differences in insertion time or failure to correctly insert the device (typical RR 0.95, 95% CI 0.17 to 5.42; 3 studies, 158 infants; very low-quality evidence). There was no difference in deaths or HIE events. AUTHORS'

conclusionsLMA can achieve effective ventilation during neonatal resuscitation in a time frame consistent with current neonatal resuscitation guidelines. Compared to BMV, LMA is more effective in terms of shorter resuscitation and ventilation times, and less need for endotracheal intubation (low- to moderate-quality evidence). However, in trials comparing LMA with BMV, over 80% of infants in both trial arms responded to the allocated intervention. In studies that allowed LMA rescue of infants failing with BMV, it was possible to avoid intubation in the majority. It is important that the clinical community resorts to the use of LMA more proactively to provide effective ventilation when newborn is not responding to BMV before attempting intubation or initiating chest compressions.LMA was found to offer comparable efficacy to endotracheal intubation (very low- to low-quality evidence). It therefore offers an alternate airway device when attempts at inserting endotracheal intubation are unsuccessful during resuscitation.Most studies enrolled infants with birth weight over 1500 g or 34 or more weeks' gestation. As such, there is lack of evidence to support LMA use in more premature infants.

Indexed as

MasksHumansHypoxia, BrainInfant, NewbornIntensive Care Units, NeonatalIntubation, IntratrachealLaryngeal MasksPositive-Pressure RespirationRandomized Controlled Trials as TopicResuscitation

Identifiers

PMID29542112
PMCPMC6494187
OpenAlexW2792975406

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.