Automated flow injection method for the high precision determination of drift tube ion mobility collision cross sections.
Article in The Analyst, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed.
- Rapid Multi-Omics for Bacterial Identification Using Flow Injection-Ion Mobility-Mass Spectrometry.Analytical chemistry · 2025Article
- High-resolution ion mobility based on traveling wave structures for lossless ion manipulation resolves hidden lipid features.Analytical and bioanalytical chemistry · 2024Article
- Synchronized Stepped Frequency Modulation for Multiplexed Ion Mobility Measurements.Journal of the American Society for Mass Spectrometry · 2022Article
- Resolving Power and Collision Cross Section Measurement Accuracy of a Prototype High-Resolution Ion Mobility Platform Incorporating Structures for Lossless Ion Manipulation.Journal of the American Society for Mass Spectrometry · 2021Article
- Assessing Collision Cross Section Calibration Strategies for Traveling Wave-Based Ion Mobility Separations in Structures for Lossless Ion Manipulations.Analytical chemistry · 2020Article
- Collision Cross Section Conformational Analyses of Bile Acids via Ion Mobility-Mass Spectrometry.Journal of the American Society for Mass Spectrometry · 2020Article
- Fundamentals of Ion Mobility-Mass Spectrometry for the Analysis of Biomolecules.Methods in molecular biology (Clifton, N.J.) · 2020Review
- Characterization of the Impact of Drug Metabolism on the Gas-Phase Structures of Drugs Using Ion Mobility-Mass Spectrometry.Analytical chemistry · 2019Article
- Ion Mobility Spectrometry in Food Analysis: Principles, Current Applications and Future Trends.Molecules (Basel, Switzerland) · 2019Review
- Ion mobility conformational lipid atlas for high confidence lipidomics.Nature communications · 2019Article
- Collision cross section compendium to annotate and predict multi-omic compound identities.Chemical science · 2019Article
- Untargeted Molecular Discovery in Primary Metabolism: Collision Cross Section as a Molecular Descriptor in Ion Mobility-Mass Spectrometry.Analytical chemistry · 2018Article
- Software Tools and Approaches for Compound Identification of LC-MS/MS Data in Metabolomics.Metabolites · 2018Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
The field of ion mobility-based omics studies requires high-quality collision cross section (CCS) libraries to effectively utilize CCS as a molecular descriptor. Absolute CCS values with the highest precision are obtained on drift tube instruments by measuring the drift time of ions at multiple drift voltages, commonly referred to as a 'stepped field' experiment. However, generating large scale absolute CCS libraries from drift tube instruments is time consuming due to the current lack of high-throughput methods. This communication reports a fully automated stepped-field method to acquire absolute CCS on commercially available equipment. Using a drift tube ion mobility-mass spectrometer (DTIM-MS) coupled to a minimally modified liquid chromatography (LC) system, CCS values can be measured online with a carefully timed flow injection analysis (FIA) experiment. Results demonstrate that the FIA stepped-field method yields CCS values which are of high analytical precision (<0.4% relative standard deviation, RSD) and accuracy (≤0.4% difference) comparable to CCS values obtained using traditional direct-infusion stepped-field experiments. This high-throughput CCS method consumes very little sample volume (20 μL) and will expedite the generation of large-scale CCS libraries to support molecular identification within global untargeted studies.