Evidence map›Paper›PMID 29540189›Full record

ArticleBiomedical engineering online2018

Camera-based photoplethysmography in an intraoperative setting.

Alexander Trumpp, Johannes Lohr, Daniel Wedekind, Martin Schmidt, Matthias Burghardt, Axel R Heller, Hagen Malberg, Sebastian Zaunseder

Abstract read
In one paragraph

Article in Biomedical engineering online, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Monitoring Pulse Rate in the Background Using Front Facing Cameras of Mobile Devices.IEEE journal of biomedical and health informatics · 2023
    Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Alexander TrumppInstitute of Biomedical Engineering, TU Dresden, Fetscherstraße 29, 01307, Dresden, Germany. alexander.trumpp@tu-dresden.de.ORCID http://orcid.org/0000-0001-7081-3371
Johannes LohrDepartment of Anesthesiology and Intensive Care Medicine, University Hospital, TU Dresden, Fetscherstraße 74, 01307, Dresden, Germany.
Daniel WedekindInstitute of Biomedical Engineering, TU Dresden, Fetscherstraße 29, 01307, Dresden, Germany.
Martin SchmidtInstitute of Biomedical Engineering, TU Dresden, Fetscherstraße 29, 01307, Dresden, Germany.
Matthias BurghardtDepartment of Anesthesiology and Intensive Care Medicine, University Hospital, TU Dresden, Fetscherstraße 74, 01307, Dresden, Germany.
Axel R HellerDepartment of Anesthesiology and Intensive Care Medicine, University Hospital, TU Dresden, Fetscherstraße 74, 01307, Dresden, Germany.
Hagen MalbergInstitute of Biomedical Engineering, TU Dresden, Fetscherstraße 29, 01307, Dresden, Germany.
Sebastian ZaunsederInstitute of Biomedical Engineering, TU Dresden, Fetscherstraße 29, 01307, Dresden, Germany.

Funding

Bundesministerium für Bildung und Forschung 03ZZ0519CSächsisches Staatsministerium für Wissenschaft und Kunst 4-7531.60/29/12
6 · The paper itself

Abstract

backgroundCamera-based photoplethysmography (cbPPG) is a measurement technique which enables remote vital sign monitoring by using cameras. To obtain valid plethysmograms, proper regions of interest (ROIs) have to be selected in the video data. Most automated selection methods rely on specific spatial or temporal features limiting a broader application. In this work, we present a new method which overcomes those drawbacks and, therefore, allows cbPPG to be applied in an intraoperative environment.

methodsWe recorded 41 patients during surgery using an RGB and a near-infrared (NIR) camera. A Bayesian skin classifier was employed to detect suitable regions, and a level set segmentation approach to define and track ROIs based on spatial homogeneity.

resultsThe results show stable and homogeneously illuminated ROIs. We further evaluated their quality with regards to extracted cbPPG signals. The green channel provided the best results where heart rates could be correctly estimated in 95.6% of cases. The NIR channel yielded the highest contribution in compensating false estimations.

conclusionsThe proposed method proved that cbPPG is applicable in intraoperative environments. It can be easily transferred to other settings regardless of which body site is considered.

Indexed as

Optical DevicesAgedFemaleHeart RateHumansIntraoperative PeriodMalePhotoplethysmographySignal-To-Noise RatioCamera-based photoplethysmographyIntraoperative monitoringLevel set methodsRemote monitoringSpatial homogeneity

Identifiers

PMID29540189
PMCPMC5853087

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.