Evidence map›Paper›PMID 29535923›Full record

ArticleJournal of medical signals and sensors

Assessment of Imprecise Small Photon Beam Modeling by Two Treatment Planning System Algorithms.

Hadi Keivan, Daryoush Shahbazi-Gahrouei, Ahmad Shanei, Alireza Amouheidari

Abstract read
In one paragraph

Article in Journal of medical signals and sensors. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. An interface tool to parametrize treatment plans for the TrueBeam radiotherapy system into TOPAS parameter control files for Monte Carlo simulation.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2024
    Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Hadi KeivanDepartment of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.
Daryoush Shahbazi-GahroueiDepartment of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.
Ahmad ShaneiDepartment of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.
Alireza AmouheidariDepartment of Radiation Oncology, Isfahan Milad Hospital, Isfahan, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDosimetric accuracy in intensity-modulated radiation therapy (IMRT) is the main part of quality assurance program. Improper beam modeling of small fields by treatment planning system (TPS) can lead to inaccuracy in treatment delivery. This study aimed to evaluate of the dose delivery accuracy at small segments of IMRT technique using two-dimensional (2D) array as well as evaluate the capability of two TPSs algorithm in modeling of small fields.

methodsIrradiation were performed using 6 MV photon beam of Siemens Artiste linear accelerator. Dosimetric behaviors of two dose calculation algorithms, namely, collapsed cone convolution/superposition (CCCS) and full scatter convolution (FSC) in small segments of IMRT plans were analyzed using a 2D diode array and gamma evaluation.

resultsComparisons of measurements against TPSs calculations showed that percentage difference of output factors of small fields were 2% and 15% for CCCS and FSC algorithm, respectively. Gamma analysis of calculated dose distributions by TPSs against those measured by 2D array showed that in passing criteria of 3 mm/3%, the mean pass rate for all segment sizes is higher than 95% except for segment sizes below 3 cm × 3 cm optimized by TiGRT TPS.

conclusionsHigh pass rate of gamma index (95%) achieved in planned small segments by Prowess relative to results obtained with TiGRT. This study showed that the accuracy of small field modeling differs between two dose calculation algorithms.

Indexed as

Dose calculation algorithmsmall-intensity modulated radiation therapy segmenttwo-dimensional array

Identifiers

PMID29535923
PMCPMC5840895

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.