ArticleClinical ophthalmology (Auckland, N.Z.)2018
Flicker electroretinograms of eyes with cataract recorded with RETeval system before and after mydriasis.
Article in Clinical ophthalmology (Auckland, N.Z.), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 3 citations in OpenAlex.
- The Mydriasis-Free Handheld ERG Device and Its Utility in Clinical Practice: A Review.Biomedicines · 2026Review
- A Diagnostic Model for Screening Diabetic Retinopathy Using the Hand-Held Electroretinogram Device RETeval.Frontiers in endocrinology · 2021Observational
- Light-Adapted Electroretinogram Differences in Autism Spectrum Disorder.Journal of autism and developmental disorders · 2020Article
- Diagnostic Performance of a Handheld Electroretinography Test for Glaucoma.Ophthalmology scienceArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe aim of this study is to determine the effect of pupil size of eyes with cataracts on the flicker electroretinograms (ERGs) elicited and recorded with the RETeval system. PATIENTS AND
methodsForty-one eyes of 41 patients (mean age, 76.5±7.3 years) that had grade 2 nuclear or cortical cataract without any other abnormalities were studied. Flicker ERGs were recorded before and after mydriatic drops instillation. The ERGs were elicited by the white light delivered at the frequency of 28.3 Hz and intensities of 2, 8, and 32 Td-s. The amplitudes and the implicit times of the flicker ERGs before and after mydriasis were compared.
resultsThere were no significant differences between the amplitudes before and after mydriasis (
conclusionThe lack of significant differences in the amplitudes and the implicit times of the flicker ERG of cataractous eyes before and after mydriasis indicated that the RETeval flicker ERGs in cataractous eyes is less affected by the pupil diameter. With our earlier study, it was assumed that the effect of cataracts on the RETeval flicker ERGs was due to the opacity of the crystalline lens, and the influence of the cataract would not be reduced or increased by mydriasis.