Evidence map›Paper›PMID 29530821›Full record

ReviewActa biomaterialia2018

Zinc-based alloys for degradable vascular stent applications.

Ehsan Mostaed, Malgorzata Sikora-Jasinska, Jaroslaw W Drelich, Maurizio Vedani

Open access · greenAbstract readReview
In one paragraph

Review in Acta biomaterialia, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 112 papers.

0numbers the graph read from it
0cells of the map it votes in
112citing papers in PubMed
18.1field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

112 citing papers in PubMed, 533 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Review
  5. Article
  6. Review
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Review
  16. Review
  17. Article
  18. Article
  19. Article
  20. Review

52 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 3 countries.

Ehsan MostaedDepartment of Materials Science and Engineering, Michigan Technological University, Houghton, MI 49931, USA; Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy. Electronic address: emostaed@mtu.edu.
Malgorzata Sikora-JasinskaDepartment of Mechanical Engineering, Politecnico di Milano, Milan, Italy; Laboratory for Biomaterials & Bioengineering (CRC-I), Department Min-Met-Materials Engineering & Research Center CHU de Québec, Laval University, Québec City, Canada.
Jaroslaw W DrelichDepartment of Materials Science and Engineering, Michigan Technological University, Houghton, MI 49931, USA.
Maurizio VedaniDepartment of Mechanical Engineering, Politecnico di Milano, Milan, Italy.
Politecnico di Milano · ITMichigan Technological University · US

Funding

Improved Biocompatibility and Biodegradation of Zn-based Stent Materials through Surface Nano-EngineeringR21EB019118 · NIBIB · MICHIGAN TECHNOLOGICAL UNIVERSITY · PI DRELICH, JAROSLAW W · 2015 to 2016
$386k
NIBIB NIH HHS R21 EB019118
6 · The paper itself

Abstract

The search for biodegradable metals with mechanical properties equal or higher to those of currently used permanent biomaterials, such as stainless steels, cobalt chromium and titanium alloys, desirable in vivo degradation rate and uniform corrosion is still an open challenge. Magnesium (Mg), iron (Fe) and zinc (Zn)-based alloys have been proposed as biodegradable metals for medical applications. Over the last two decades, extensive research has been done on Mg and Fe. Fe-based alloys show appropriate mechanical properties, but their degradation rate is an order of magnitude below the benchmark value. In comparison, alongside the insufficient mechanical performance of most of its alloys, Mg degradation rate has proven to be too high in a physiological environment and corrosion is rarely uniform. During the last few years, Zn alloys have been explored by the biomedical community as potential materials for bioabsorbable vascular stents due to their tolerable corrosion rates and tunable mechanical properties. This review summarizes recent progress made in developing Zn alloys for vascular stenting application. Novel Zn alloys are discussed regarding their microstructural characteristics, mechanical properties, corrosion behavior and in vivo performance. STATEMENT OF SIGNIFICANCE: Numerous studies on magnesium and iron materials have been reported to date, in an effort to formulate bioabsorbable stents with tailorable mechanical characteristics and corrosion behavior. Crucial concerns regarding poor ductility and remarkably rapid corrosion of magnesium, and very slow degradation of iron, seem to be still not desirably fulfilled. Zinc was introduced as a potential implant material in 2013 due to its promising biodegradability and biocompatibility. Since then, extensive investigations have been made toward development of zinc alloys that meet clinical benchmarks for vascular scaffolding. This review critically surveys the zinc alloys developed since 2013 from metallurgical and biodegradation points of view. Microstructural features, mechanical, corrosion and in vivo performances of these new alloys are thoroughly reviewed and evaluated.

Indexed as

Absorbable ImplantsBlood Vessel ProsthesisAlloysAnimalsHumansStentsZincAlloysZincBioabsorbableDegradationMechanical propertiesMicrostructureZinc alloys

Identifiers

PMID29530821
PMCPMC5927626
OpenAlexW2790284808

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.