ArticleClinical orthopaedics and related research2018
Femoral Component External Rotation Affects Knee Biomechanics: A Computational Model of Posterior-stabilized TKA.
Article in Clinical orthopaedics and related research, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 28 citations in OpenAlex.
- Magnitude of intraoperative femoral rotational adjustment from the initial plan is associated with slower early recovery after robotic-assisted functional-alignment TKA.Journal of robotic surgery · 2026Article
- Balanced Medial Collateral Ligament (MCL) Length, Not Intrinsic Laxity, Governs Load Sharing and Kinematics in Mechanically Aligned Posterior-Stabilized TKA.Annals of biomedical engineering · 2026Article
- Role of relative intentional rotation of the femoral component in robotic-assisted primary total knee arthroplasty as a tool for the correction of medial flexion laxity.Journal of robotic surgery · 2026Article
- The transepicondylar axis or the posterior condylar axis: Which is the best reference for femoral component rotation in robotic-assisted total knee arthroplasty?Arthroplasty (London, England) · 2026Article
- Impacts of medial collateral ligament (MCL) stiffness adjustment on knee joint mechanics in mechanically aligned posterior-substituting (PS) total knee arthroplasty (TKA).Biomedical engineering letters · 2025Article
- The Role of Computed Tomography in Achieving True External Rotation in Robotic Knee Replacement: A Retrospective Analysis of 300 Knees.Journal of orthopaedic case reports · 2025Article
- Can robotic arm-assisted total knee arthroplasty be applied to valgus deformity.Archives of orthopaedic and trauma surgery · 2025Article
- Effect of Posterior Cruciate Ligament Resection on Gap Balancing in Robot-assisted Total Knee Arthroplasty.Orthopaedic surgery · 2024Article
- Anatomical Reference of the Femur after Distal Resection Is Reliable for Rotational Alignment in Total Knee Arthroplasty.Journal of personalized medicine · 2024Article
- Bayesian Calibration of Computational Knee Models to Estimate Subject-Specific Ligament Properties, Tibiofemoral Kinematics, and Anterior Cruciate Ligament Force With Uncertainty Quantification.Journal of biomechanical engineering · 2023Article
- Kinetic Sensors for Ligament Balance and Kinematic Evaluation in Anatomic Bi-Cruciate Stabilized Total Knee Arthroplasty.Sensors (Basel, Switzerland) · 2021Article
- Incidental findings detected on preoperative CT imaging obtained for robotic-assisted joint replacements: clinical importance and the effect on the scheduled arthroplasty.Skeletal radiology · 2021Article
- Simulation of preoperative flexion contracture in a computational model of total knee arthroplasty: Development and evaluation.Journal of biomechanics · 2021Article
- A geometric ratio to predict the flexion gap in total knee arthroplasty.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2020Article
- Effect of surgical parameters on the biomechanical behaviour of bicondylar total knee endoprostheses - A robot-assisted test method based on a musculoskeletal model.Scientific reports · 2019Article
- Posterior condylar bone resection and femoral implant thickness vary by up to 3 mm across implant systems: implications for flexion gap balancing.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2019Article
Corrections and comments
- Commented on by
Authors and funding
8 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe correct amount of external rotation of the femoral component during TKA is controversial because the resulting changes in biomechanical knee function associated with varying degrees of femoral component rotation are not well understood. We addressed this question using a computational model, which allowed us to isolate the biomechanical impact of geometric factors including bony shapes, location of ligament insertions, and implant size across three different knees after posterior-stabilized (PS) TKA. QUESTIONS/PURPOSES: Using a computational model of the tibiofemoral joint, we asked: (1) Does external rotation unload the medial collateral ligament (MCL) and what is the effect on lateral collateral ligament tension? (2) How does external rotation alter tibiofemoral contact loads and kinematics? (3) Does 3° external rotation relative to the posterior condylar axis align the component to the surgical transepicondylar axis (sTEA) and what anatomic factors of the femoral condyle explain variations in maximum MCL tension among knees?
methodsWe incorporated a PS TKA into a previously developed computational knee model applied to three neutrally aligned, nonarthritic, male cadaveric knees. The computational knee model was previously shown to corroborate coupled motions and ligament loading patterns of the native knee through a range of flexion. Implant geometries were virtually installed using hip-to-ankle CT scans through measured resection and anterior referencing surgical techniques. Collateral ligament properties were standardized across each knee model by defining stiffness and slack lengths based on the healthy population. The femoral component was externally rotated from 0° to 9° relative to the posterior condylar axis in 3° increments. At each increment, the knee was flexed under 500 N compression from 0° to 90° simulating an intraoperative examination. The computational model predicted collateral ligament forces, compartmental contact forces, and tibiofemoral internal/external and varus-valgus rotation through the flexion range.
resultsThe computational model predicted that femoral component external rotation relative to the posterior condylar axis unloads the MCL and the medial compartment; however, these effects were inconsistent from knee to knee. When the femoral component was externally rotated by 9° rather than 0° in knees one, two, and three, the maximum force carried by the MCL decreased a respective 55, 88, and 297 N; the medial contact forces decreased at most a respective 90, 190, and 570 N; external tibial rotation in early flexion increased by a respective 4.6°, 1.1°, and 3.3°; and varus angulation of the tibia relative to the femur in late flexion increased by 8.4°, 8.0°, and 7.9°, respectively. With 3° of femoral component external rotation relative to the posterior condylar axis, the femoral component was still externally rotated by up to 2.7° relative to the sTEA in these three neutrally aligned knees. Variations in MCL force from knee to knee with 3° of femoral component external rotation were related to the ratio of the distances from the femoral insertion of the MCL to the posterior and distal cuts of the implant; the closer this ratio was to 1, the more uniform were the MCL tensions from 0° to 90° flexion.
conclusionsA larger ratio of distances from the femoral insertion of the MCL to the posterior and distal cuts may cause clinically relevant increases in both MCL tension and compartmental contact forces. CLINICAL RELEVANCE: To obtain more consistent ligament tensions through flexion, it may be important to locate the posterior and distal aspects of the femoral component with respect to the proximal insertion of the MCL such that a ratio of 1 is achieved.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.