Evaluation of the Leap Motion Controller during the performance of visually-guided upper limb movements.

Ewa Niechwiej-Szwedo, David Gonzalez, Mina Nouredanesh, James Tung

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed, 1 pooled it
4.1field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

21 citing papers in PubMed, 1 synthesis or guideline pooled it, 66 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Trial
  4. Trial
  5. Article
  6. Article
  7. Article
  8. Accuracy of Video-Based Hand Tracking for People With Upper-Body Disabilities.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2024
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Ewa Niechwiej-SzwedoDepartment of Kinesiology, University of Waterloo, Waterloo, Canada.ORCID 0000-0002-5293-5161
David GonzalezDepartment of Kinesiology, University of Waterloo, Waterloo, Canada.
Mina NouredaneshDepartment of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Canada.
James TungDepartment of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Canada.
University of Waterloo · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Kinematic analysis of upper limb reaching provides insight into the central nervous system control of movements. Until recently, kinematic examination of motor control has been limited to studies conducted in traditional research laboratories because motion capture equipment used for data collection is not easily portable and expensive. A recently developed markerless system, the Leap Motion Controller (LMC), is a portable and inexpensive tracking device that allows recording of 3D hand and finger position. The main goal of this study was to assess the concurrent reliability and validity of the LMC as compared to the Optotrak, a criterion-standard motion capture system, for measures of temporal accuracy and peak velocity during the performance of upper limb, visually-guided movements. In experiment 1, 14 participants executed aiming movements to visual targets presented on a computer monitor. Bland-Altman analysis was conducted to assess the validity and limits of agreement for measures of temporal accuracy (movement time, duration of deceleration interval), peak velocity, and spatial accuracy (endpoint accuracy). In addition, a one-sample t-test was used to test the hypothesis that the error difference between measures obtained from Optotrak and LMC is zero. In experiment 2, 15 participants performed a Fitts' type aiming task in order to assess whether the LMC is capable of assessing a well-known speed-accuracy trade-off relationship. Experiment 3 assessed the temporal coordination pattern during the performance of a sequence consisting of a reaching, grasping, and placement task in 15 participants. Results from the t-test showed that the error difference in temporal measures was significantly different from zero. Based on the results from the 3 experiments, the average temporal error in movement time was 40±44 ms, and the error in peak velocity was 0.024±0.103 m/s. The limits of agreement between the LMC and Optotrak for spatial accuracy measures ranged between 2-5 cm. Although the LMC system is a low-cost, highly portable system, which could facilitate collection of kinematic data outside of the traditional laboratory settings, the temporal and spatial errors may limit the use of the device in some settings.

Indexed as

MovementAdultBiomechanical PhenomenaEquipment DesignFemaleFingersHandHumansMalePhotic StimulationReproducibility of ResultsUser-Computer InterfaceYoung Adult

Identifiers

PMID29529064
PMCPMC5846796
OpenAlexW2792355154

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.