Evidence map›Paper›PMID 29526856›Full record

ArticleRestorative neurology and neuroscience2018

A wearable resistive robot facilitates locomotor adaptations during gait.

Edward P Washabaugh, Chandramouli Krishnan

Open access · greenAbstract read
In one paragraph

Article in Restorative neurology and neuroscience, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
2.6field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 32 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. The "Journal of functional morphology and kinesiology · 2020
    Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 2 countries.

Edward P WashabaughDepartment of Physical Medicine and Rehabilitation, NeuRRo Lab, Michigan Medicine, Ann Arbor, MI, USA.
Chandramouli KrishnanDepartment of Physical Medicine and Rehabilitation, NeuRRo Lab, Michigan Medicine, Ann Arbor, MI, USA.
Institute of Neurobiology · BGUniversity of Michigan–Ann Arbor · US

Funding

Techniques DevelopmentP2CHD086844 · NICHD · MEDICAL UNIVERSITY OF SOUTH CAROLINA · PI GEORGE, MARK S · 2015 to 2024
$12.7M
NRI: Wearable eMbots to Induce Recovery of FunctionR01EB019834 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI DURFEE, WILLIAM K, GILLESPIE, RICHARD BRENT · 2014 to 2016
$854k
Functional Resistance Training during Gait: A Novel Intervention to Improve Knee Function after ACL ReconstructionR21HD092614 · NICHD · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI KRISHNAN, CHANDRAMOULI, PALMIERI-SMITH, RIANN MARIE · 2017 to 2018
$428k
NIBIB NIH HHS R01 EB019834NICHD NIH HHS P2C HD086844NICHD NIH HHS R21 HD092614
6 · The paper itself

Abstract

backgroundRobotic-resisted treadmill walking is a form of task-specific training that has been used to improve gait function in individuals with neurological injury, such as stroke, spinal cord injury, or cerebral palsy. Traditionally, these devices use active elements (e.g., motors or actuators) to provide resistance during walking, making them bulky, expensive, and less suitable for overground or in-home rehabilitation. We recently developed a low-cost, wearable robotic brace that generates resistive torques across the knee joint using a simple magnetic brake. However, the possible effects of training with this device on gait function in a clinical population are currently unknown.

objectiveThe purpose of this study was to test the acute effects of resisted walking with this device on kinematics, muscle activation patterns, and gait velocity in chronic stroke survivors.

methodsSix stroke survivors wore the resistive brace and walked on a treadmill for 20 minutes (4×5 minutes) at their self-selected walking speed while simultaneously performing a foot trajectory-tracking task to minimize stiff-knee gait. Electromyography, sagittal plane gait kinematics, and overground gait velocity were collected to evaluate the acute effects of the device on gait function.

resultsRobotic-resisted treadmill training resulted in a significant increase in quadriceps and hamstring EMG activity during walking. Significant aftereffects (i.e., improved joint excursions) were also observed on the hip and knee kinematics, which persisted for several steps after training. More importantly, training resulted in significant improvements in overground gait velocity. These results were consistent in all the subjects tested.

conclusionThis study provides preliminary evidence indicating that robotic-resisted treadmill walking using our knee brace can result in meaningful biomechanical aftereffects that translate to overground walking.

Indexed as

Stroke RehabilitationWearable Electronic DevicesAgedElectromyographyEvoked Potentials, MotorExercise TestFemaleGait Disorders, NeurologicHumansMaleMiddle AgedMuscle, SkeletalRecovery of FunctionRoboticsStrokeactive engagementEMGfunctional resistance trainingrehabilitationRehab roboticstask-specific

Identifiers

PMID29526856
PMCPMC5903686
OpenAlexW2790826993

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.