Validation of refraction and anterior segment parameters by a new multi-diagnostic platform (VX120).
Article in Journal of optometry. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed.
- Prevalence of Refractive Errors, Myopic Macular Degeneration, and Associated Risk Factors in a Maltese Population-Based Study.Clinical optometry · 2026Article
- The prevalence of amblyopia and associated factors in older adults in The Malta Eye Study.Scientific reports · 2025Article
- Refractive assessment by wavefront aberrometry compared to subjective refraction in PRK patients.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2025Article
- Comparing Close-Field and Open-Field Autorefractometry and Subjective Refraction.Journal of clinical medicine · 2025Article
- Markedly Lower Rates of Age-Related Macular Degeneration in Malta Compared to European Countries: Results from The Malta Eye Study, Indicating Possible Divergent Genetic Ancestry?Clinical ophthalmology (Auckland, N.Z.) · 2025Article
- Safety, Efficacy, and Visual Performance of an Orthokeratology Lens with Increased Compression Factor.Journal of clinical medicine · 2024Article
- Advanced Optical Wavefront Technologies to Improve Patient Quality of Vision and Meet Clinical Requests.Polymers · 2022Review
- Contrast sensitivity and higher-order aberrations in Keratoconus subjects.Scientific reports · 2021Article
- Relationship between Axial Length and Corneo-Scleral Topography: A Preliminary Study.Diagnostics (Basel, Switzerland) · 2021Article
- Repeatability of non-invasive break-up time measures with a new automated dry eye platform in healthy eyes.International ophthalmology · 2020Article
- Intrasession repeatability of pupil size measurements under different light levels provided by a multidiagnostic device in healthy eyes.BMC ophthalmology · 2020Article
- The prevalence of corneal abnormalities in first-degree relatives of patients with keratoconus: a prospective case-control study.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2020Article
- Average gradient of Zernike polynomials over polygons.Optics express · 2020Article
- Repeatability of Aberrometry-Based Automated Subjective Refraction in Healthy and Keratoconus Subjects.Journal of ophthalmology · 2020Article
- Comparison of Two Wavefront Autorefractors: Binocular Open-Field versus Monocular Closed-Field.Journal of ophthalmology · 2020Article
- The prevalence of refractive errors in college students in Israel.Journal of optometryArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe VX120 (Visionix Luneau, France) is a novel multi-diagnostic platform that combines Hartmann-Shack based autorefraction, Placido-disk based corneal-topography and anterior segment measurements made with a stationary-Scheimpflug camera. We investigate the agreement between different parameters measured by the VX120 with accepted or gold-standard techniques to test if they are interchangeable, as well as to evaluate the repeatability and reproducibility.
methodsThe right-eyes of healthy subjects were included in the study. Autorefraction of the VX120 was compared to subjective refraction. Agreement of anterior segment parameters was compared to the Sirius (CSO, Italy) including autokeratometry, central corneal thickness (CCT), iridiocorneal angle (IA). Inter and intra-test repeatability of the above parameters was assessed. Results were analyzed using Bland and Altman analyses.
resultsA total of 164 eyes were evaluated. The mean difference between VX120 autorefraction and subjective refraction for sphere, spherical equivalent (SE), and cylinder was 0.01±0.43D, 0.14±0.47D, and -0.26±0.30D, respectively and high correlation was found to all parameter (r>0.75) except for J
conclusionsThe VX120 provides consistent refraction and most anterior segment measurements in normal healthy eyes, with high levels of intra and inter-session repeatability.