Trial reportAnatolian journal of cardiology2018
Surface electrogram-guided left ventricular lead placement improves response to cardiac resynchronization therapy.
Trial report in Anatolian journal of cardiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 1 synthesis or guideline pooled it, 8 citations in OpenAlex.
- Targeted left ventricular lead positioning to the site of latest activation in cardiac resynchronization therapy: a systematic review and meta-analysis.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023Pooled it
- The role of guidance in delivering cardiac resynchronization therapy: A systematic review and network meta-analysis.Heart rhythm O2 · 2022Article
- Determinants of LV dP/dtOpen heart · 2021Observational
- The Evolving Role of Electrocardiography in Cardiac Resynchronization Therapy.Current treatment options in cardiovascular medicine · 2019Review
- Optimization of Lead Placement in the Right Ventricle During Cardiac Resynchronization Therapy. A Simulation Study.Frontiers in physiology · 2019Article
- QRS narrowing and prediction of response to cardiac resynchronization therapy.Anatolian journal of cardiology · 2018Article
- Author`s Reply.Anatolian journal of cardiology · 2018Article
Corrections and comments
- Commented on by
- Commented on by
Authors and funding
11 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveFailure to select the optimal left ventricular (LV) segment for lead implantation is one of the most important causes of unresponsiveness to the cardiac resynchronization therapy (CRT). In our study, we aimed to investigate the echocardiographic and clinical benefits of LV lead implantation guided by an intraoperative 12-lead surface electrocardiogram (ECG) in patients with multiple target veins.
methodsWe included 80 [42 (62.5%) male] heart failure patients who successfully underwent CRT defibrillator (CRT-D) implantation. Patients were divided into two groups. In group 1, LV lead was positioned at the site with the shortest biventricular-paced (BiV-paced) QRS duration (QRSd), as intraprocedurally measured using surface ECG. In group 2 (control), we included patients who underwent the standard unguided CRT. ECG, echocardiogram, and functional status were evaluated before and 6 months after CRT implantation in all patients.
resultsIn group 1, BiV-paced QRSd measurements were successfully performed in 112 of 120 coronary sinus branches during CRT and an LV lead was successfully placed at the optimal site in all patients. Compared with group 2, group 1 had a significantly higher rate (85% vs. 50%, p=0.02) of response (>15% reduction in LV end-systolic volume) to CRT as well as a shorter QRSd (p<0.001) and a greater QRS shortening (ΔQRS) associated with CRT compared with baseline (p<0.001). The mean New York Heart Association functional class was significantly improved in both groups, and no significant differences were found in clinical response to CRT (85% vs. 70%, p=0.181).
conclusionSurface ECG can be used to guide LV lead placement in patients with multiple target veins for improving response to CRT. Thus, it is a safe, feasible, and economic approach for CRT-D implantation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.