Evidence map›Paper›PMID 29520182›Full record

ArticleKorean journal of radiology

Self-Gated Late Gadolinium Enhancement at 7T to Image Rats with Reperfused Acute Myocardial Infarction.

Lei Wang, Yushu Chen, Bing Zhang, Wei Chen, Chunhua Wang, Li Song, Ziqian Xu, Jie Zheng, Fabao Gao

Abstract read
In one paragraph

Article in Korean journal of radiology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Guideline
  2. Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Lei WangMolecular Imaging Center, West China Hospital of Sichuan University, Chengdu 610041, China.
Yushu ChenDepartment of Radiology, West China Hospital of Sichuan University, Chengdu 610041, China.
Bing ZhangDepartment of Radiology, West China Hospital of Sichuan University, Chengdu 610041, China.
Wei ChenDepartment of Radiology, West China Hospital of Sichuan University, Chengdu 610041, China.
Chunhua WangDepartment of Radiology, West China Hospital of Sichuan University, Chengdu 610041, China.
Li SongMolecular Imaging Center, West China Hospital of Sichuan University, Chengdu 610041, China.
Ziqian XuDepartment of Radiology, West China Hospital of Sichuan University, Chengdu 610041, China.
Jie ZhengMallinckrodt Institute of Radiology, Washington University School of Medicine in St. Louis, MO 63110, USA.
Fabao GaoDepartment of Radiology, West China Hospital of Sichuan University, Chengdu 610041, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: A failed electrocardiography (ECG)-trigger often leads to a long acquisition time (TA) and deterioration in image quality. The purpose of this study was to evaluate and optimize the technique of self-gated (SG) cardiovascular magnetic resonance (CMR) for cardiac late gadolinium enhancement (LGE) imaging of rats with myocardial infarction/reperfusion. Materials and Methods: Cardiovascular magnetic resonance images of 10 rats were obtained using SG-LGE or ECG with respiration double-gating (ECG-RESP-gating) method at 7T to compare differences in image interference and TA between the two methods. A variety of flip angles (FA: 10°-80°) and the number of repetitions (NR: 40, 80, 150, and 300) were investigated to determine optimal scan parameters of SG-LGE technique based on image quality score and contrast-to-noise ratio (CNR). Results: Self-gated late gadolinium enhancement allowed successful scan in 10 (100%) rats. However, only 4 (40%) rats were successfully scanned with the ECG-RESP-gating method. TAs with SG-LGE varied depending on NR used (TA: 41, 82, 154, and 307 seconds, corresponding to NR of 40, 80, 150, and 300, respectively). For the ECG-RESP-gating method, the average TA was 220 seconds. For SG-LGE images, CNR (42.5 ± 5.5, 43.5 ± 7.5, 54 ± 9, 59.5 ± 8.5, 56 ± 13, 54 ± 8, and 41 ± 9) and image quality score (1.85 ± 0.75, 2.20 ± 0.83, 2.85 ± 0.37, 3.85 ± 0.52, 2.8 ± 0.51, 2.45 ± 0.76, and 1.95 ± 0.60) were achieved with different FAs (10°, 15°, 20°, 25°, 30°, 35°, and 40°, respectively). Optimal FAs of 20°-30° and NR of 80 were recommended. Conclusion: Self-gated technique can improve image quality of LGE without irregular ECG or respiration gating. Therefore, SG-LGE can be used an alternative method of ECG-RESP-gating.

Indexed as

Magnetic Resonance ImagingAnimalsContrast MediaElectrocardiographyGadoliniumImage EnhancementMaleMyocardial InfarctionRatsRats, Sprague-DawleyContrast MediaGadolinium7TAnimal studiesFlip angleLate gadolinium enhancementMRIMyocardial infarctionSelf-gated

Identifiers

PMID29520182
PMCPMC5840053

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.