ArticleNature communications2018
Design and validation of a foldable and photovoltaic wide-field epiretinal prosthesis.
Article in Nature communications, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 66 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
66 citing papers in PubMed, 183 citations in OpenAlex.
- Bioelectronic interfaces for restoring vision pathways.Materials today. Bio · 2026Review
- Photovoltaic Stimulation of Mouse and Pig Retina With Pyrolytic Carbon Microelectrodes Integrated on High-Density Silicon Solar Cell Arrays.Advanced healthcare materials · 2026Article
- Bioinspired Photodetectors: From Nature to Advanced Applications.Advanced materials (Deerfield Beach, Fla.) · 2026Review
- A flexible arched artificial photoreceptor constructed by photodeformable liquid crystal polymers and its application in vision restoration.Smart molecules : open access · 2026Article
- Advances in neuroprostheses: interfaces, materials, and applications.Nano convergence · 2026Review
- Intraocular Micro-LED Epiretinal Projection for Anterior Segment Blindness: Design and Large-Animal Feasibility Study.Bioengineering (Basel, Switzerland) · 2026Article
- Photovoltaic nanoassembly of nanowire arrays sensitized with colloidal nanocrystals for near-infrared retina photostimulation.Science advances · 2026Article
- Advances in artificial vision systems: a comprehensive review of technologies, applications, and future directions.Biomedical engineering letters · 2025Review
- Development of a Biodegradable Green Emitter Chitosan-Based OLED for Implantable Biomedical Devices.ACS applied materials & interfaces · 2025Article
- Biomechanics characterization of an implantable ultrathin intracortical electrode through finite element method.Scientific reports · 2025Article
- Machine Learning Techniques for Simulating Human Psychophysical Testing of Low-Resolution Phosphene Face Images in Artificial Vision.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Article
- Nitrogen-Doped Ultrananocrystalline Diamond - Optoelectronic Biointerface for Wireless Neuronal Stimulation.Advanced healthcare materials · 2025Article
- Design, Fabrication, and Surgical Testing of the 3D-Printed Large-Array Port-System for the Implantation of Large Epiretinal Stimulators.Translational vision science & technology · 2025Article
- Visual Prostheses in the Era of Artificial Intelligence Technology.Eye and brain · 2025Review
- Article
- Ultrathin rubbery bio-optoelectronic stimulators for untethered cardiac stimulation.Science advances · 2024Article
- Perspectives on non-genetic optoelectronic modulation biointerfaces for advancing healthcare.Med-X · 2024Article
- Noninvasive imaging-guided ultrasonic neurostimulation with arbitrary 2D patterns and its application for high-quality vision restoration.Nature communications · 2024Article
- Article
- An actor-model framework for visual sensory encoding.Nature communications · 2024Article
6 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Retinal prostheses have been developed to fight blindness in people affected by outer retinal layer dystrophies. To date, few hundred patients have received a retinal implant. Inspired by intraocular lenses, we have designed a foldable and photovoltaic wide-field epiretinal prosthesis (named POLYRETINA) capable of stimulating wireless retinal ganglion cells. Here we show that within a visual angle of 46.3 degrees, POLYRETINA embeds 2215 stimulating pixels, of which 967 are in the central area of 5 mm, it is foldable to allow implantation through a small scleral incision, and it has a hemispherical shape to match the curvature of the eye. We demonstrate that it is not cytotoxic and respects optical and thermal safety standards; accelerated ageing shows a lifetime of at least 2 years. POLYRETINA represents significant progress towards the improvement of both visual acuity and visual field with the same device, a current challenging issue in the field.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials