Evidence map›Paper›PMID 29516353›Full record

ArticleInternational journal of computer assisted radiology and surgery2018

A cable-driven parallel manipulator with force sensing capabilities for high-accuracy tissue endomicroscopy.

Kiyoteru Miyashita, Timo Oude Vrielink, George Mylonas

Open access · hybridAbstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 14 citations in OpenAlex.

  1. A novel contact optimization algorithm for endomicroscopic surface scanning.International journal of computer assisted radiology and surgery · 2024
    Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Kiyoteru MiyashitaHARMS Lab, Department of Surgery and Cancer, Imperial College London, 3rd Floor Paterson Wing, 20 South Wharf Road, W2 1PF, London, UK.
Timo Oude VrielinkHARMS Lab, Department of Surgery and Cancer, Imperial College London, 3rd Floor Paterson Wing, 20 South Wharf Road, W2 1PF, London, UK. t.oude-vrielink15@imperial.ac.uk.ORCID http://orcid.org/0000-0002-1153-4425
George MylonasHARMS Lab, Department of Surgery and Cancer, Imperial College London, 3rd Floor Paterson Wing, 20 South Wharf Road, W2 1PF, London, UK.
Imperial College London · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeEndomicroscopy (EM) provides high resolution, non-invasive histological tissue information and can be used for scanning of large areas of tissue to assess cancerous and pre-cancerous lesions and their margins. However, current robotic solutions do not provide the accuracy and force sensitivity required to perform safe and accurate tissue scanning.

methodsA new surgical instrument has been developed that uses a cable-driven parallel mechanism (CPDM) to manipulate an EM probe. End-effector forces are determined by measuring the tensions in each cable. As a result, the instrument allows to accurately apply a contact force on a tissue, while at the same time offering high resolution and highly repeatable probe movement.

results0.2 and 0.6 N force sensitivities were found for 1 and 2 DoF image acquisition methods, respectively. A back-stepping technique can be used when a higher force sensitivity is required for the acquisition of high quality tissue images. This method was successful in acquiring images on ex vivo liver tissue.

conclusionThe proposed approach offers high force sensitivity and precise control, which is essential for robotic EM. The technical benefits of the current system can also be used for other surgical robotic applications, including safe autonomous control, haptic feedback and palpation.

Indexed as

Equipment DesignAnimalsCattleEndoscopyFeedbackLiverMechanical PhenomenaMicroscopyMicrosurgeryPalpationRobotic Surgical ProceduresSurgical InstrumentsAutonomous scanningCable-driven parallel mechanismsEndomicroscopyForce sensing

Identifiers

PMID29516353
PMCPMC5953980
OpenAlexW2963290471

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.