ArticleJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2018
Precision of automated QRS duration measurement in patients treated with cardiac resynchronization therapy.
Article in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 2 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
Abstract
purposeShortening of the QRS duration (QRSd) is often used to guide device optimization and reprogramming in patients with cardiac resynchronization therapy (CRT). Detecting the small changes expected during reprogramming requires that the QRSd can be measured with high precision, but this has never been studied in patients with CRT. In this study, we wanted to assess the precision of automated QRSd measurement in patients treated with CRT using two commonly available electrocardiographs.
methodsPatients treated with CRT were recruited during routine follow-up in our pacemaker clinic. In all participants, a number of immediate successive ECGs were recorded with the GE MAC 5500 (Mac55) and the GE MAC 1600 (Mac16). Data were analyzed with a linear mixed model.
resultsA total of 785 12-lead ECGs were recorded in 36 patients with an average of 11.2 and 10.6 ECGs per patient with the Mac55 and Mac16, respectively. The Mac55 measured the QRSd longer by 10.3 milliseconds (ms) (95% CI 7.1-13.5 ms, p < 0.001) and with significantly smaller standard deviation for repeated measurements (6.3 vs. 10.4 ms, p < 0.001). Limits of agreement were ± 17.5 and ± 28.8 ms for the Mac55 and Mac16, respectively.
conclusionsAutomated measurement of QRSd in patients with CRT shows low precision with limits of agreement of ± 17.5 and ± 28.8 ms for repeated measurements in two commercially available electrocardiographs. Device programming solely by QRSd changes should be done with caution, and clinical effects should be demonstrated in future trials. Device programming based on QRSd changes should be done with caution until the ability of this measure to predict clinical outcome can be demonstrated in prospective study.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.