SynthesisInternational wound journal2018
Prevention of pressure ulcers with a static air support surface: A systematic review.
Synthesis in International wound journal, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06294327 (Comparing a REactive STatic Air Mattress to an Alternating Air Pressure Mattress in the Prevention of Pressure Ulcers), which is not on this map. Cited by 11 papers, 7 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Comparing a REactive STatic Air Mattress to an Alternating Air Pressure Mattress in the Prevention of Pressure Ulcers: a Randomized Controlled Trial (RESTART)
Who cites it
11 citing papers in PubMed, 7 syntheses or guidelines pooled it, 1 citations in OpenAlex.
- Summary of best evidence for prevention and control of pressure ulcer on support surfaces.International wound journal · 2023Pooled it
- Alternating pressure (active) air surfaces for preventing pressure ulcers.The Cochrane database of systematic reviews · 2021Pooled it
- Beds, overlays and mattresses for treating pressure ulcers.The Cochrane database of systematic reviews · 2021Pooled it
- Reactive air surfaces for preventing pressure ulcers.The Cochrane database of systematic reviews · 2021Pooled it
- Foam surfaces for preventing pressure ulcers.The Cochrane database of systematic reviews · 2021Pooled it
- Alternative reactive support surfaces (non-foam and non-air-filled) for preventing pressure ulcers.The Cochrane database of systematic reviews · 2021Pooled it
- Prevention of pressure ulcers with a static air support surface: A systematic review.International wound journal · 2018Pooled it
- Independent risk factors for pressure ulcer development in a high-risk nursing home population receiving evidence-based pressure ulcer prevention: Results from a study in 26 nursing homes in Belgium.International wound journal · 2019Trial
- Can a prolonged healing pressure injury be benefited by using an AI mattress? A case study.BMC geriatrics · 2024Article
- Article
- An exploration of nursing home residents' experiences of a non-powered static air mattress overlay to prevent pressure ulcers.International wound journal · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The aims of this study were to identify, assess, and summarise available evidence about the effectiveness of static air mattress overlays to prevent pressure ulcers. The primary outcome was the incidence of pressure ulcers. Secondary outcomes included costs and patient comfort. This study was a systematic review. Six electronic databases were consulted: Cochrane Library, EMBASE, PubMed (Medline), CINAHL (EBSCOhost interface), Science direct, and Web of Science. In addition, a hand search through reviews, conference proceedings, and the reference lists of the included studies was performed to identify additional studies. Potential studies were reviewed and assessed by 2 independent authors based on the title and abstract. Decisions regarding inclusion or exclusion of the studies were based on a consensus between the authors. Studies were included if the following criteria were met: reporting an original study; the outcome was the incidence of pressure ulcer categories I to IV when using a static air mattress overlay and/or in comparison with other pressure-redistribution device(s); and studies published in English, French, and Dutch. No limitation was set on study setting, design, and date of publication. The methodological quality assessment was evaluated using the Critical Appraisal Skills Program Tool. Results were reported in a descriptive way to reflect the exploratory nature of the review. The searches included 13 studies: randomised controlled trials (n = 11) and cohort studies (n = 2). The mean pressure ulcer incidence figures found in the different settings were, respectively, 7.8% pressure ulcers of categories II to IV in nursing homes, 9.06% pressure ulcers of categories I to IV in intensive care settings, and 12% pressure ulcers of categories I to IV in orthopaedic wards. Seven comparative studies reported a lower incidence in the groups of patients on a static air mattress overlay. Three studies reported a statistical (P < .1) lower incidence compared with a standard hospital mattress (10 cm thick, density 35 kg/m
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.