ArticleInternational orthopaedics2018
Higher prevalence of periprosthetic fractures with ceramic on polyethylene hip bearing compared with ceramic on ceramic on the contralateral side: a forty year experience with hip osteonecrosis.
Article in International orthopaedics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 9 citations in OpenAlex.
- Stem cell therapy in bilateral osteonecrosis: computer-assisted surgery versus conventional fluoroscopic technique on the contralateral side.International orthopaedics · 2018Trial
- Revision in Ceramic-on-Ceramic and Ceramic-on-Polyethylene Bearing in Primary Total Hip Arthroplasty with Press-fit Cups: A Systematic Review and Meta-analysis of Different Methodological Study Designs.The archives of bone and joint surgery · 2022Review
- The impact of polyethylene abrasion on the occurrence of periprosthetic proximal femoral fractures in patients with total hip arthroplasty.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2021Article
- Total hip arthroplasty for sickle cell osteonecrosis: guidelines for perioperative management.EFORT open reviews · 2020Review
- Hip osteonecrosis: stem cells for life or behead and arthroplasty?International orthopaedics · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeIt is unclear whether late THA periprosthetic femoral fractures are related to a mechanical mechanism that decreases strength of the femur (for example, loosening) or to a biological problem as osteolysis. It is also unknown if ceramic on ceramic bearing couples decrease the risk of late periprosthetic fractures as a result of the absence of wear and osteolysis. MATERIAL AND
methodsWe therefore asked whether the cumulative long-term fractures were different according to the couple of friction ceramic on ceramic or ceramic on polyethylene in 327 patients (654 hips) with bilateral THA (one ceramic-ceramic, and the contralateral ceramic-polyethylene) who had THA with cemented stems performed between from 1978 to 2000 for osteonecrosis.
resultsThere were two intra-operative fractures (0.3%). The median follow-up was 22 years (range, 15-40 years), and at the most recent follow-up, the cumulative number of late (after 7 years of follow-up) post-operative fractures was 32 (5% of 654 hips). Fractures were unilateral, which means for the 327 patients, a 10% rate of fractures. Periprosthetic fractures increased in number with follow-up: seven fractures (1% of 654 hips) occurred within ten years of THA implantation, 20 (3%) within 20 years, 26 (4%) within 30 years, and 32 (5%) within 40 years. The risk of fracture was influenced (p < 0.001) by the bearing surfaces at the time of prosthetic implantation, low (0.3%) for ceramic on ceramic (1/32 fractures; 1/327 hips), high (10%) for ceramic on PE (31/32 fractures; 31/327 hips).
conclusionIn summary, when the contralateral hip of the same patient is the control, after 40 years of follow-up, post-operative fractures occur 30 times more often on the side with PE cup than on the side with ceramic/ceramic bearing.
Indexed as
Identifiers