ArticleJournal of clinical laboratory analysis2018
Concordance between point-of-care blood gas analysis and laboratory autoanalyzer in measurement of hemoglobin and electrolytes in critically ill patients.
Article in Journal of clinical laboratory analysis, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 22 citations in OpenAlex.
- Improper arterial catheter blood sampling method affects hemoglobin test results: A cautionary tale.The Journal of international medical research · 2025Article
- A Retrospective Database Analysis to Investigate if Electrolytes in Venous Blood are Equivalent to the Levels in Arterial Blood.Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine · 2024Article
- Article
- Agreement of Potassium, Sodium, Glucose, and Hemoglobin Measured by Blood Gas Analyzer With Dry Chemistry Analyzer and Complete Blood Count Analyzer: A Two-Center Retrospective Analysis.Frontiers in medicine · 2022Article
- The effect of heparin concentration on results of venous blood gas of patients admitted to cardiac intensive care unit: A double-blind clinical trial.BioMedicine · 2022Article
- Article
- Intra-patient potassium variability after hypothermic cardiac arrest: a multicentre, prospective study.Scandinavian journal of trauma, resuscitation and emergency medicine · 2019Article
- A Milestone in Point of Care Capillary Blood Glucose Monitoring of Critically Ill Hospitalized Patients.Journal of diabetes science and technology · 2018Article
- Concordance between point-of-care blood gas analysis and laboratory autoanalyzer in measurement of hemoglobin and electrolytes in critically ill patients.Journal of clinical laboratory analysis · 2018Article
Corrections and comments
- Erratum issuedCorrigendum.2019
Authors and funding
6 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundWe tested the hypothesis that the results of the same test performed on point-of-care blood gas analysis (BGA) machine and automatic analyzer (AA) machine in central laboratory have high degree of concordance in critical care patients and that the two test methods could be used interchangeably.
methodsWe analyzed 9398 matched pairs of BGA and AA results, obtained from 1765 patients. Concentration pairs of the following analytes were assessed: hemoglobin, glucose, sodium, potassium, chloride, and bicarbonate. We determined the agreement using concordance correlation coefficient (CCC) and Bland-Altman analysis. The difference in results was also assessed against the United States Clinical Laboratory Improvement Amendments (US-CLIA) 88 rules. The test results were considered to be interchangeable if they were within the US-CLIA variability criteria and would not alter the clinical management when compared to each other.
resultsThe median time interval between sampling for BGA and AA in each result pair was 5 minutes. The CCC values ranged from 0.89(95% CI 0.89-0.90) for chloride to 0.98(95% CI 0.98-0.99) for hemoglobin. The largest bias was for hemoglobin. The limits of agreement relative to bias were largest for sodium, with 3.4% of readings outside the US-CLIA variation rule. The number of readings outside the US-CLIA acceptable variation was highest for glucose (7.1%) followed by hemoglobin (5.9%) and chloride (5.2%).
conclusionWe conclude that there is moderate to substantial concordance between AA and BGA machines on tests performed in critically ill patients. However, the two tests methods cannot be used interchangeably, except for potassium.