Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06293157 (Carbon Fiber Transpedicular Screws in Treatment of Spinal Metastatic Disease and Stereotactic Radiotherapy - a Prospective, Randomized Trial), which is not on this map. Cited by 45 papers.

0numbers the graph read from it
0cells of the map it votes in
45citing papers in PubMed
8.5field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06293157 narecruitingnot on this mapstarted 2023, after this paper: background citation

Carbon Fiber Transpedicular Screws in Treatment of Spinal Metastatic Disease and Stereotactic Radiotherapy - a Prospective, Randomized Trial

TypeinterventionalSponsorCopernicus Memorial HospitalRan2023 to 2033Enrolled226ConditionsMetastatic Spinal Cord Compression, Metastasis SpineArmsTranspedicular spinal stabilization - carbon fibers-based implants, Transpedicular spinal stabilization - titanium implants, Stereotactic body radiotherapy
3 · Its place in the literature

Who cites it

45 citing papers in PubMed, 101 citations in OpenAlex.

  1. Trial
  2. Neurophysiological characteristics of carbon PEEK screws in patients with spinal metastatic disease.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Article
  3. Biomechanical effects of lateral pedicle wall violation and subsequent screw redirection on pedicle screw anchorage.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Article
  4. Review
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Article
  17. Article
  18. Observational
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Richard A LindtnerDepartment of Trauma Surgery, Medical University of Innsbruck, Anichstraße 35, 6020, Innsbruck, Austria.
Rene SchmidDepartment of Trauma Surgery, Medical University of Innsbruck, Anichstraße 35, 6020, Innsbruck, Austria.
Thomas Nydeggericotec ag, Industriestraße 12, 9450, Altstätten, Switzerland.
Marko KonschakeDivision of Clinical and Functional Anatomy, Department of Anatomy, Histology and Embryology, Medical University of Innsbruck, Müllerstraße 59, 6020, Innsbruck, Austria.
Werner SchmoelzDepartment of Trauma Surgery, Medical University of Innsbruck, Anichstraße 35, 6020, Innsbruck, Austria. werner.schmoelz@i-med.ac.at.ORCID http://orcid.org/0000-0003-2962-2594
Innsbruck Medical University · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposePedicle screw loosening is a common and significant complication after posterior spinal instrumentation, particularly in osteoporosis. Radiolucent carbon fiber-reinforced polyetheretherketone (CF/PEEK) pedicle screws have been developed recently to overcome drawbacks of conventional metallic screws, such as metal-induced imaging artifacts and interference with postoperative radiotherapy. Beyond radiolucency, CF/PEEK may also be advantageous over standard titanium in terms of pedicle screw loosening due to its unique material properties. However, screw anchorage and loosening of CF/PEEK pedicle screws have not been evaluated yet. The aim of this biomechanical study therefore was to evaluate whether the use of this alternative nonmetallic pedicle screw material affects screw loosening. The hypotheses tested were that (1) nonmetallic CF/PEEK pedicle screws resist an equal or higher number of load cycles until loosening than standard titanium screws and that (2) PMMA cement augmentation further increases the number of load cycles until loosening of CF/PEEK screws.

methodsIn the first part of the study, left and right pedicles of ten cadaveric lumbar vertebrae (BMD 70.8 mg/cm

resultsThe nonmetallic CF/PEEK pedicle screws resisted a similar number of load cycles until loosening as the contralateral standard titanium screws (3701 ± 1228 vs. 3751 ± 1614 load cycles, p = 0.89). PMMA cement augmentation of CF/PEEK pedicle screws furthermore significantly increased the mean number of load cycles until loosening by 1.63-fold (5100 ± 1933 in augmented vs. 3130 ± 2132 in nonaugmented CF/PEEK screws, p = 0.015). In addition, angular screw motion assessed by stress fluoroscopy was significantly smaller in augmented than in nonaugmented CF/PEEK screws before as well as after failure.

conclusionsUsing nonmetallic CF/PEEK instead of standard titanium as pedicle screw material did not affect screw loosening in the chosen test setup, whereas cement augmentation enhanced screw anchorage of CF/PEEK screws. While comparable to titanium screws in terms of screw loosening, radiolucent CF/PEEK pedicle screws offer the significant advantage of not interfering with postoperative imaging and radiotherapy. These slides can be retrieved under Electronic Supplementary Material.

Indexed as

AgedAged, 80 and overBenzophenonesBiomechanical PhenomenaBone CementsCadaverCarbon FiberFemaleFluoroscopyHumansKetonesLumbar VertebraeMaleMaterials TestingMiddle AgedPedicle ScrewsBenzophenonesBone CementsCarbon FiberKetonespolyetheretherketonePolyethylene GlycolsPolymersTitaniumBiomechanicsCarbon fiber-reinforced PEEKCyclic loadingElastic modulusOsteoporosisPedicle screwPedicle screw augmentationPedicle screw looseningPEEKPolyetheretherketonePosterior instrumentationSpinal tumorsSpine