ArticleAJNR. American journal of neuroradiology2018
Normal Values of Magnetic Relaxation Parameters of Spine Components with the Synthetic MRI Sequence.
Article in AJNR. American journal of neuroradiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed.
- Development, validation, and pilot MRI safety study of a high-resolution, open source, whole body pediatric numerical simulation model.PloS one · 2021Trial
- Effect of basis choice on quantitative parameter estimation in accelerated subspace reconstructions.Magnetic resonance letters · 2026Article
- Quantifying Cardiac, Respiratory, and Low Frequency Components of CSF Motion From fMRI Inflow Effects.Magnetic resonance in medicine · 2026Article
- Multi-parametric quantitative MRI for characterizing of lumbar intervertebral disc high-intensity zones in patients with chronic low back pain.Journal of orthopaedic surgery and research · 2026Article
- Rapid multiparametric quantitative MRI for predicting the activity of thyroid-associated ophthalmopathy: combination with clinical characteristics.European radiology · 2025Article
- Synthetic MR: Clinical applications in neuroradiology.Neuroradiology · 2025Review
- T1 mapping for Head and Neck Cancer Patients undergoing Chemoradiotherapy: Feasibility of 3D Stack of Star Imaging.Magnetic resonance imaging · 2024Article
- Imaging Role in Diagnosis, Prognosis, and Treatment Response Prediction Associated with High-grade Glioma.Journal of medical signals and sensors · 2024Review
- The Effect of the Human Brainstem Myelination on Gait Speed in Normative Aging.The journals of gerontology. Series A, Biological sciences and medical sciences · 2023Article
- Application of magnetic resonance image compilation (MAGiC) in the diagnosis of middle-aged and elderly women with osteoporosis.BMC medical imaging · 2023Article
- Characterization of meningiomas with synthetic imaging.Brain and behavior · 2022Article
- Optimized multi-echo gradient-echo magnetic resonance imaging for gray and white matter segmentation in the lumbosacral cord at 3 T.Scientific reports · 2022Article
- Article
- Synthetic MRI in the detection and quantitative evaluation of sacroiliac joint lesions in axial spondyloarthritis.Frontiers in immunology · 2022Article
- Application of MAGnetic resonance imaging compilation in acute ischemic stroke.World journal of clinical cases · 2021Article
- Spinal disorders mimicking infection.Insights into imaging · 2021Review
- T2 relaxation time shortening in the cochlea of patients with sudden sensory neuronal hearing loss: a retrospective study using quantitative synthetic magnetic resonance imaging.European radiology · 2021Article
- A preliminary study of synthetic magnetic resonance imaging in rectal cancer: imaging quality and preoperative assessment.Insights into imaging · 2021Article
- Quantitative magnetic resonance imaging: differentiating soft tissue implants and fillers used in cosmetic and reconstructive surgery.Skeletal radiology · 2021Article
- Generative models: an upcoming innovation in musculoskeletal radiology? A preliminary test in spine imaging.European radiology experimental · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background and purposeSyMRI is a technique developed to perform quantitative MR imaging. Our aim was to analyze its potential use for measuring relaxation times of normal components of the spine and to compare them with values found in the literature using relaxometry and other techniques. MATERIALS AND
methodsThirty-two spine MR imaging studies (10 cervical, 5 dorsal, 17 lumbosacral) were included. A modified multiple-dynamic multiple-echo sequence was added and processed to obtain quantitative T1 (millisecond), T2 (millisecond), and proton density (percentage units [pu]) maps for each patient. An ROI was placed on representative areas for CSF, spinal cord, intervertebral discs, and vertebral bodies, to measure their relaxation.
resultsRelaxation time means are reported for CSF (T1 = 4273.4 ms; T2 = 1577.6 ms; proton density = 107.5 pu), spinal cord (T1 = 780.2 ms; T2 = 101.6 ms; proton density = 58.7 pu), normal disc (T1 = 1164.9 ms; T2 = 101.9 ms; proton density = 78.9 pu), intermediately hydrated disc (T1 = 723 ms; T2 = 66.8 ms; proton density = 60.8 pu), desiccated disc (T1 = 554.4 ms; T2 = 55.6 ms; proton density = 47.6 ms), and vertebral body (T1 = 515.3 ms; T2 = 100.8 ms; proton density = 91.1 pu). Comparisons among the mean T1, T2, and proton density values showed significant differences between different spinal levels (cervical, dorsal, lumbar, and sacral) for CSF (proton density), spinal cord (T2 and proton density), normal disc (T1, T2, and proton density), and vertebral bodies (T1 and proton density). Significant differences were found among mean T1, T2, and proton density values of normal, intermediately hydrated, and desiccated discs.
conclusionsMeasurements can be easily obtained on SyMRI and correlated with previously published values obtained using conventional relaxometry techniques.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.