Evidence map›Paper›PMID 29495462›Full record

ArticleMaterials (Basel, Switzerland)2018

Comparison of Six Different Silicones In Vitro for Application as Glaucoma Drainage Device.

Claudia Windhövel, Lisa Harder, Jan-Peter Bach, Michael Teske, Niels Grabow, Thomas Eickner, Ulf Hinze, Boris Chichkov, Ingo Nolte

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Claudia WindhövelSmall Animal Clinic, University of Veterinary Medicine Hannover, Foundation, D-30559 Hannover, Germany. claudia.windhoevel@tiho-hannover.de.
Lisa HarderSmall Animal Clinic, University of Veterinary Medicine Hannover, Foundation, D-30559 Hannover, Germany. lisa.harder@tiho-hannover.de.
Jan-Peter BachSmall Animal Clinic, University of Veterinary Medicine Hannover, Foundation, D-30559 Hannover, Germany. jan-peter.bach@tiho-hannover.de.
Michael TeskeInstitute for Biomedical Engineering, Rostock University Medical Center, D-18119 Rostock, Germany. michael.teske@uni-rostock.de.
Niels GrabowInstitute for Biomedical Engineering, Rostock University Medical Center, D-18119 Rostock, Germany. niels.grabow@uni-rostock.de.
Thomas EicknerInstitute for Biomedical Engineering, Rostock University Medical Center, D-18119 Rostock, Germany. thomas.eickner@uni-rostock.de.
Ulf HinzeLaser Zentrum Hannover e.V., D-30419 Hannover, Germany. u.hinze@lzh.de.ORCID 0000-0002-0944-1561
Boris ChichkovLaser Zentrum Hannover e.V., D-30419 Hannover, Germany. chichkov@iqo.uni-hannover.de.
Ingo NolteSmall Animal Clinic, University of Veterinary Medicine Hannover, Foundation, D-30559 Hannover, Germany. ingo.nolte@tiho-hannover.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Silicones are widely used in medical applications. In ophthalmology, glaucoma drainage devices are utilized if conservative therapies are not applicable or have failed. Long-term success of these devices is limited by failure to control intraocular pressure due to fibrous encapsulation. Therefore, different medical approved silicones were tested in vitro for cell adhesion, cell proliferation and viability of human Sclera (hSF) and human Tenon fibroblasts (hTF). The silicones were analysed also depending on the sample preparation according to the manufacturer's instructions. The surface quality was characterized with environmental scanning electron microscope (ESEM) and water contact angle measurements. All silicones showed homogeneous smooth and hydrophobic surfaces. Cell adhesion was significantly reduced on all silicones compared to the negative control. Proliferation index and cell viability were not influenced much. For development of a new glaucoma drainage device, the silicones Silbione LSR 4330 and Silbione LSR 4350, in this study, with low cell counts for hTF and low proliferation indices for hSF, and silicone Silastic MDX4-4210, with low cell counts for hSF and low proliferation indices for hTF, have shown the best results in vitro. Due to the high cell adhesion shown on Silicone LSR 40, 40,026, this material is unsuitable.

Indexed as

40,026fibrosisglaucomaLSR 40Med-4234Silastic MDX4-4210Silbione LSR 4330Silbione LSR 4350siliconeSILUPRAN 2445A/B

Identifiers

PMID29495462
PMCPMC5872920

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked