ArticleJournal of infusion nursing : the official publication of the Infusion Nurses Society
Antimicrobial Efficacy of a New Chlorhexidine-based Device Against Staphylococcus aureus Colonization of Venous Catheters.
Article in Journal of infusion nursing : the official publication of the Infusion Nurses Society. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 8 citations in OpenAlex.
- Chlorhexidine locking device for central line infection prevention in ICU patients: protocol for an open-label pilot and feasibility randomized controlled trial.Pilot and feasibility studies · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Vascular catheters are a major cause of nosocomial bloodstream infections. ChloraLock (ATTWILL Medical Solutions, Inc, West Jordan, UT, and ICU Medical, Inc, San Clemente, CA) is a novel antimicrobial device containing chlorhexidine digluconate (CHG) that is fitted onto a syringe and infuses CHG into the catheter lumen during locking. The objective of this study was to evaluate the antimicrobial efficacy of ChloraLock with in vitro tests and its ability to reduce Staphylococcus aureus contamination of catheters in the external jugular veins of Yorkshire swine. ChloraLock significantly reduced the bacterial load in the in vitro tests by up to 6 log10 colony-forming units (CFU) and by 3 to 4 log10 CFU/lumen in vivo in a swine model with 0.9% NaCl catheter locks.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.