ArticleJournal of medical imaging (Bellingham, Wash.)2018
Signal dropout correction-based ultrasound segmentation for diastolic mitral valve modeling.
Article in Journal of medical imaging (Bellingham, Wash.), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Automatic 4D mitral valve segmentation from transesophageal echocardiography: a semi-supervised learning approach.Medical & biological engineering & computing · 2026Article
- Segmentation of Tricuspid Valve Leaflets From Transthoracic 3D Echocardiograms of Children With Hypoplastic Left Heart Syndrome Using Deep Learning.Frontiers in cardiovascular medicine · 2021Article
- Combining position-based dynamics and gradient vector flow for 4D mitral valve segmentation in TEE sequences.International journal of computer assisted radiology and surgery · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Three-dimensional ultrasound segmentation of mitral valve (MV) at diastole is helpful for duplicating geometry and pathology in a patient-specific dynamic phantom. The major challenge is the signal dropout at leaflet regions in transesophageal echocardiography image data. Conventional segmentation approaches suffer from missing sonographic data leading to inaccurate MV modeling at leaflet regions. This paper proposes a signal dropout correction-based ultrasound segmentation method for diastolic MV modeling. The proposed method combines signal dropout correction, image fusion, continuous max-flow segmentation, and active contour segmentation techniques. The signal dropout correction approach is developed to recover the missing segmentation information. Once the signal dropout regions of TEE image data are recovered, the MV model can be accurately duplicated. Compared with other methods in current literature, the proposed algorithm exhibits lower computational cost. The experimental results show that the proposed algorithm gives competitive results for diastolic MV modeling compared with conventional segmentation algorithms, evaluated in terms of accuracy and efficiency.