Implantation of Neural Probes in the Brain Elicits Oxidative Stress.
Article in Frontiers in bioengineering and biotechnology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 61 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
61 citing papers in PubMed, 97 citations in OpenAlex.
- MicroFace maps microglial morphology remodeling, revealing spatial zones and bifurcated trajectories during brain microinjury recovery.iScience · 2026Article
- RORA Targeting PRNP Modulates Age-Related Cataract via Activation Oxidative Injury-Induced Cellular Senescence and Apoptosis of Lens Epithelial Cells.Aging cell · 2026Article
- Antimicrobial coated intracortical probes reduce invading microbe abundance and subsequent neuroinflammation.Biomaterials · 2026Article
- Lipid nanoparticle-mediated Cd14 siRNA delivery ameliorates the acute inflammatory response to intracortical microelectrode implantation.Acta biomaterialia · 2026Article
- Multi-omic spatially resolved analysis of the neuroinflammatory response to intracortical microelectrode arrays.Biomaterials · 2026Article
- Spatial transcriptomics on an expanded dataset at the brain-electrode interface: exploration of variability and identification of novel biomarkers.Frontiers in neuroscience · 2026Article
- Dexamethasone-loaded platelet-inspired nanoparticles improve intracortical microelectrode recording performance.Nature communications · 2025Article
- Piezo1 and Piezo2 Ion Channels in Neuronal and Astrocytic Responses to MEA Implants in the Rat Somatosensory Cortex.International journal of molecular sciences · 2025Article
- DiffCoRank: a comprehensive framework for discovering hub genes and differential gene co-expression in brain implant-associated tissue responses.BMC bioinformatics · 2025Article
- Revolutionizing brain‒computer interfaces: overcoming biocompatibility challenges in implantable neural interfaces.Journal of nanobiotechnology · 2025Review
- Effects of iron accumulation and its chelation on oxidative stress in intracortical implants.Acta biomaterialia · 2025Article
- Systemically administered platelet-inspired nanoparticles to reduce inflammation surrounding intracortical microelectrodes.Biomaterials · 2025Article
- Mechanically-adaptive, resveratrol-eluting neural probes for improved intracortical recording performance and stability.Npj flexible electronics · 2025Article
- Enhancing biocompatibility of the brain-machine interface: A review.Bioactive materials · 2024Review
- Interface-Mediated Neurogenic Signaling: The Impact of Surface Geometry and Chemistry on Neural Cell Behavior for Regenerative and Brain-Machine Interfacing Applications.Advanced materials (Deerfield Beach, Fla.) · 2024Review
- Comprehensive proteomic analysis of the differential expression of 62 proteins following intracortical microelectrode implantation.Scientific reports · 2024Article
- Flexible Polymer Electrodes for Stable Prosthetic Visual Perception in Mice.Advanced healthcare materials · 2024Article
- Structural, Functional, and Genetic Changes Surrounding Electrodes Implanted in the Brain.Accounts of chemical research · 2024Article
- Transparent and Conformal Microcoil Arrays for Spatially Selective Neuronal Activation.Device · 2024Article
- Effects of Micromachining on Anti-oxidant Elution from a Mechanically-Adaptive Polymer.Journal of micromechanics and microengineering : structures, devices, and systems · 2024Article
1 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 2 institutions in 1 country.
Funding
Abstract
Clinical implantation of intracortical microelectrodes has been hindered, at least in part, by the perpetual inflammatory response occurring after device implantation. The neuroinflammatory response observed after device implantation has been correlated to oxidative stress that occurs due to neurological injury and disease. However, there has yet to be a definitive link of oxidative stress to intracortical microelectrode implantation. Thus, the objective of this study is to give direct evidence of oxidative stress following intracortical microelectrode implantation. This study also aims to identify potential molecular targets to attenuate oxidative stress observed postimplantation. Here, we implanted adult rats with silicon non-functional microelectrode probes for 4 weeks and compared the oxidative stress response to no surgery controls through postmortem gene expression analysis and qualitative histological observation of oxidative stress markers. Gene expression analysis results at 4 weeks postimplantation indicated that EH domain-containing 2, prion protein gene (Prnp), and Stearoyl-Coenzyme A desaturase 1 (Scd1) were all significantly higher for animals implanted with intracortical microelectrode probes compared to no surgery control animals. To the contrary, NADPH oxidase activator 1 (Noxa1) relative gene expression was significantly lower for implanted animals compared to no surgery control animals. Histological observation of oxidative stress showed an increased expression of oxidized proteins, lipids, and nucleic acids concentrated around the implant site. Collectively, our results reveal there is a presence of oxidative stress following intracortical microelectrode implantation compared to no surgery controls. Further investigation targeting these specific oxidative stress linked genes could be beneficial to understanding potential mechanisms and downstream therapeutics that can be utilized to reduce oxidative stress-mediated damage following microelectrode implantation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials