ArticleACS sensors2018

Carbon Nanotube Strain Sensor Based Hemoretractometer for Blood Coagulation Testing.

Zida Li, Yize Wang, Xufeng Xue, Brendan McCracken, Kevin Ward, Jianping Fu

Abstract read
In one paragraph

Article in ACS sensors, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yize Wang
Xufeng Xue
Brendan McCracken
Kevin Ward

Funding

Microfluidic Functional Immunophenotyping of Pediatric Patients Following CardiopR01HL119542 · NHLBI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI CORNELL, TIMOTHY T, FU, JIANPING · 2014 to 2017
$2.7M
NHLBI NIH HHS R01 HL119542
6 · The paper itself

Abstract

Coagulation monitoring is essential for perioperative care and thrombosis treatment. However, existing assays for coagulation monitoring have limitations such as a large footprint and complex setup. In this work, we developed a miniaturized device for point-of-care blood coagulation testing by measuring dynamic clot retraction force development during blood clotting. In this device, a blood drop was localized between a protrusion and a flexible force-sensing beam to measure clot retraction force. The beam was featured with micropillar arrays to assist the deposition of carbon nanotube films, which served as a strain sensor to achieve label-free electrical readout of clot retraction force in real time. We characterized mechanical and electrical properties of the force-sensing beam and optimized its design. We further demonstrated that this blood coagulation monitoring device could obtain results that were consistent with those using an imaging method and that the device was capable of differentiating blood samples with different coagulation profiles. Owing to its low fabrication cost, small size, and low consumption of blood samples, the blood coagulation testing device using carbon nanotube strain sensors holds great potential as a point-of-care tool for future coagulation monitoring.

Indexed as

Blood CoagulationBlood Coagulation TestsEquipment DesignHumansNanotubes, CarbonPoint-of-Care SystemsNanotubes, Carbonblood coagulationcarbon nanotubeclot retraction forcepoint-of-care diagnosticsstrain sensor

Identifiers

PMID29485284
PMCPMC6223013