ArticleJournal of neural engineering2018
Evaluating the in vivo glial response to miniaturized parylene cortical probes coated with an ultra-fast degrading polymer to aid insertion.
Article in Journal of neural engineering, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 24 citations in OpenAlex.
- Interface-Mediated Neurogenic Signaling: The Impact of Surface Geometry and Chemistry on Neural Cell Behavior for Regenerative and Brain-Machine Interfacing Applications.Advanced materials (Deerfield Beach, Fla.) · 2024Review
- Beyond Tissue replacement: The Emerging role of smart implants in healthcare.Materials today. Bio · 2023Review
- Recent Progress in Materials Chemistry to Advance Flexible Bioelectronics in Medicine.Advanced materials (Deerfield Beach, Fla.) · 2022Review
- jULIEs: nanostructured polytrodes for low traumatic extracellular recordings and stimulation in the mammalian brain.Journal of neural engineering · 2022Article
- A flexible neural implant with ultrathin substrate for low-invasive brain-computer interface applications.Microsystems & nanoengineering · 2022Article
- Intracortical Microelectrode Array Unit Yield under Chronic Conditions: A Comparative Evaluation.Micromachines · 2021Review
- The Future of Neuroscience: Flexible and Wireless Implantable Neural Electronics.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2021Review
- Fabrication of a Multilayer Implantable Cortical Microelectrode Probe to Improve Recording Potential.Journal of microelectromechanical systems : a joint IEEE and ASME publication on microstructures, microactuators, microsensors, and microsystems · 2021Article
- More Than Cell Markers: Understanding Heterogeneous Glial Responses to Implantable Neural Devices.Frontiers in cellular neuroscience · 2021Article
- A Critical Review of Microelectrode Arrays and Strategies for Improving Neural Interfaces.Advanced healthcare materials · 2019Review
- A graphical user interface to assess the neuroinflammatory response to intracortical microelectrodes.Journal of neuroscience methods · 2019Article
- Flexible and Stretchable Bio-Integrated Electronics Based on Carbon Nanotube and Graphene.Materials (Basel, Switzerland) · 2018Review
Corrections and comments
- Erratum issued
Authors and funding
13 authors at 1 institution in 1 country.
Funding
Abstract
objectiveDespite the feasibility of short-term neural recordings using implantable microelectrodes, attaining reliable, chronic recordings remains a challenge. Most neural recording devices suffer from a long-term tissue response, including gliosis, at the device-tissue interface. It was hypothesized that smaller, more flexible intracortical probes would limit gliosis by providing a better mechanical match with surrounding tissue. APPROACH: This paper describes the in vivo evaluation of flexible parylene microprobes designed to improve the interface with the adjacent neural tissue to limit gliosis and thereby allow for improved recording longevity. The probes were coated with an ultrafast degrading tyrosine-derived polycarbonate (E5005(2K)) polymer that provides temporary mechanical support for device implantation, yet degrades within 2 h post-implantation. A parametric study of probes of varying dimensions and polymer coating thicknesses were implanted in rat brains. The glial tissue response and neuronal loss were assessed from 72 h to 24 weeks post-implantation via immunohistochemistry. MAIN
resultsExperimental results suggest that both probe and polymer coating sizes affect the extent of gliosis. When an appropriate sized coating dimension (100 µm × 100 µm) and small probe (30 µm × 5 µm) was implanted, a minimal post-implantation glial response was observed. No discernible gliosis was detected when compared to tissue where a sham control consisting of a solid degradable polymer shuttle of the same dimensions was inserted. A larger polymer coating (200 µm × 200 µm) device induced a more severe glial response at later time points, suggesting that the initial insertion trauma can affect gliosis even when the polymer shuttle degrades rapidly. A larger degree of gliosis was also observed when comparing a larger sized probe (80 µm × 5 µm) to a smaller probe (30 µm × 5 µm) using the same polymer coating size (100 µm × 100 µm). There was no significant neuronal loss around the implantation sites for most device candidates except the group with largest polymer coating and probe sizes. SIGNIFICANCE: These results suggest that: (1) the degree of mechanical trauma at device implantation and mechanical mismatches at the probe-tissue interface affect long term gliosis; (2) smaller, more flexible probes may minimize the glial response to provide improved tissue biocompatibility when used for chronic neural signal recording; and (3) some degree of glial scarring did not significantly affect neuronal distribution around the probe.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.