Biomechanical evaluation of cervical disc replacement with a novel prosthesis based on the physiological curvature of endplate.

Jigang Lou, Yuanchao Li, Beiyu Wang, Yang Meng, Quan Gong, Hao Liu

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.7field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Jigang LouDepartment of Orthopedics, West China Hospital, Sichuan University, 37 Guoxue Road, Chengdu, Sichuan, 610041, China.
Yuanchao LiDepartment of Biomechanical Research Laboratory, Shanghai Jiao Tong University, Shanghai, China.
Beiyu WangDepartment of Orthopedics, West China Hospital, Sichuan University, 37 Guoxue Road, Chengdu, Sichuan, 610041, China.
Yang MengDepartment of Orthopedics, West China Hospital, Sichuan University, 37 Guoxue Road, Chengdu, Sichuan, 610041, China.
Quan GongDepartment of Orthopedics, West China Hospital, Sichuan University, 37 Guoxue Road, Chengdu, Sichuan, 610041, China.
Hao LiuDepartment of Orthopedics, West China Hospital, Sichuan University, 37 Guoxue Road, Chengdu, Sichuan, 610041, China. liuhao110@126.com.
West China Hospital of Sichuan University · CNSichuan University · CNShanghai Jiao Tong University · CN

Funding

the grant from the foundation of Science & Technology Department of Sichuan Province 0040205301C35
6 · The paper itself

Abstract

backgroundMost of the current available cervical disc prostheses present a flat surface instead of an arcuate surface which is most similar to the morphology of cervical endplate. Therefore, we designed a novel prosthesis (Pretic-I, Trauson) based on the physiological curvature of the cervical endplate. Biomechanical evaluation of cervical disc replacement (CDR) with this novel prosthesis was performed and compared with the Prestige LP prosthesis.

methodsThree motion segments of 18 cadaveric cervical specimens (C2-C7) were evaluated with a 75 N follower load. Overall, the biomechanics of three models, intact specimen, CDR with the novel prosthesis and CDR with the Prestige LP prosthesis, were studied to gain insight into the effective function of the novel prosthesis. The range of motion (ROM) of all three segments and intradiscal pressure (IDP) on adjacent levels were measured and analysed.

resultsCompared to the intact condition, the ROM of all three segments showed no significant difference in the replacement group. Moreover, there was also no significant difference in the ROM between the two prostheses. Besides, the IDP on the cranial adjacent level showed no obvious difference between the two prostheses; nevertheless, the IDP on the caudal adjacent level of the novel prosthesis was significantly less than the Prestige LP prosthesis.

conclusionsIn summary, the novel disc prosthesis was effective to maintain the ROM at the target segment and adjacent segments. Besides, CDR with the novel prosthesis could reduce the IDP on the caudal adjacent level to a certain extent, compared with the Prestige LP prosthesis.

Indexed as

AdultAgedBiomechanical PhenomenaCervical VertebraeDiskectomyFemaleHumansIntervertebral DiscMaleMiddle AgedProsthesis DesignTotal Disc ReplacementBiomechanicsCervical disc replacementDisc prosthesisIntradiscal pressureRange of motion

Identifiers

PMID29482611
PMCPMC5828121
OpenAlexW2788204930

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.