SynthesisKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2018
Posterior-stabilized inserts are preferable to cruciate-substituting ultracongruent inserts due to more favourable kinematics and stability.
Synthesis in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Equivalent outcomes of ultra-congruent and standard cruciate-retaining inserts in total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2022Pooled it
- Rotating hinge knee versus constrained condylar knee in revision total knee arthroplasty: A meta-analysis.PloS one · 2019Pooled it
- No differences in clinical outcomes or isokinetic performance between cruciate-substituting ultra-congruent and posterior stabilized total knee arthroplasties: a randomized controlled trial.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2021Trial
- Anterior-stabilized TKA is inferior to posterior-stabilized TKA in terms of postoperative posterior stability and knee flexion in osteoarthritic knees: a prospective randomized controlled trial with bilateral TKA.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2020Trial
- Do Ultracongruent Inserts Reproduce the Intraoperative Sagittal Plane Kinematics of Posterior Stabilized TKR? Assessment Using a Modern Robotic System.Indian journal of orthopaedics · 2025Article
- No difference in patient-reported outcomes or range of motion between ultracongruent and posterior stabilized total knee arthroplasty: A randomized controlled trial.Journal of experimental orthopaedics · 2024Article
- Article
- Clinical relevance of roll-back replacement of ultra congruent total knee arthroplasty: comparison of mid-term outcomes with posterior stabilizing design.Archives of orthopaedic and trauma surgery · 2023Article
- Favorable outcomes of posterior cruciate-stabilized inserts over ultracongruent inserts in total knee arthroplasty.Archives of orthopaedic and trauma surgery · 2023Article
- Modern Total Knee Arthroplasty Bearing Designs and the Role of the Posterior Cruciate Ligament.Arthroplasty today · 2023Article
- Similar outcomes including maximum knee flexion between mobile bearing condylar-stabilised and fixed bearing posterior-stabilised prosthesis: a case control study.Journal of experimental orthopaedics · 2022Article
- Comparison of Functional Outcomes, Femoral Rollback and Sagittal Stability of Anterior-Stabilized Versus Posterior-Stabilized Total Knee Arthroplasty: A Systematic Review and Meta-analysis of Randomized Controlled Trials.Indian journal of orthopaedics · 2021Review
- Sagittal radius of curvature, trochlea design and ultracongruent insert in total knee arthroplasty.EFORT open reviews · 2019Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeIt is unknown whether the conforming superiority of ultracongruent (UC) inserts over posterior stabilized (PS) inserts, due to an increased anterior lip for prevention of anterior displacement of the condyles during knee flexion, leads to better knee scores or greater knee stability in arthroplasty patients. This meta-analysis compared clinical outcomes, intraoperative kinematics, sagittal stability, and range of motion (ROM) between groups with either UC or PS inserts in primary total knee arthroplasty (TKA).
methodsStudies that recorded clinical outcomes, intraoperative kinematics, sagittal stability, and ROM in patients who underwent primary TKA with UC or PS inserts were included in the meta-analysis. Subgroup analyses based on differences in flexion angles were performed for intraoperative kinematics.
resultsThirteen studies met the criteria for inclusion in the meta-analysis. The UC and PS insert groups reported similar pain scores (95% CI - 0.15 to 0.16; n.s.) and function scores (95% CI - 0.30 to 0.14; n.s.). In contrast, femoral rotation during flexion (95% CI - 0.06 to 6.35; p = 0.05), posterior femoral translation during flexion (95% CI - 2.74 to - 0.15; p = 0.03), tibial sagittal laxity at 90° (95% CI 2.91 to 7.72; p < 0.0001), and ROM (95% CI - 4.84 to - 1.53; p = 0.0002) differed significantly between the groups. Subgroup analyses revealed that the pooled data for femoral rotation were significantly different between groups: 60°, 4.09 (p < 0.00001); 90°, 7.94 (p < 0.00001); and 120°, 8.16 (p < 0.00001). Furthermore, pooled data for posterior femoral translation were significantly different between groups: 90°, - 3.70 (p < 0.00001); and 120°, - 3.96 (p < 0.00001).
conclusionsThere were no significant differences in clinical outcomes between the groups with UC and PS inserts. However, the UC insert group showed significantly greater external femoral rotation, less posterior femoral translation, greater tibial laxity in the sagittal plane, and less ROM than the PS insert group. Based on the results of the current meta-analysis, in substituting the PCL, PS inserts are preferable to UC inserts due to more favourable kinematics and stability, even though both inserts have equivalent clinical outcomes. LEVEL OF EVIDENCE: Therapeutic study, Level II.
Indexed as
Identifiers
29459998What OpenQuestion holds
Registered trials