Evidence map›Paper›PMID 29455244›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2018

Rotation of intramedullary alignment rods affects distal femoral cutting plane in total knee arthroplasty.

Günther Maderbacher, Jan Matussek, Armin Keshmiri, Felix Greimel, Clemens Baier, Joachim Grifka, Hermann Maderbacher

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.7field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Günther MaderbacherDepartment of Orthopaedic Surgery, University of Regensburg, Regensburg, Germany. Guenther.Maderbacher@klinik.uni-regensburg.de.
Jan MatussekDepartment of Orthopaedic Surgery, University of Regensburg, Regensburg, Germany.
Armin KeshmiriDepartment of Orthopaedic Surgery, University of Regensburg, Regensburg, Germany.
Felix GreimelDepartment of Orthopaedic Surgery, University of Regensburg, Regensburg, Germany.
Clemens BaierDepartment of Orthopaedic Surgery, University of Regensburg, Regensburg, Germany.
Joachim GrifkaDepartment of Orthopaedic Surgery, University of Regensburg, Regensburg, Germany.
Hermann MaderbacherMontanuniversität Leoben, Leoben, Austria.
University of Regensburg · DEMontanuniversität Leoben · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeIntramedullary rods are widely used to align the distal femoral cut in total knee arthroplasty. We hypothesised that both coronal (varus/valgus) and sagittal (extension/flexion) cutting plane are affected by rotational changes of intramedullary femoral alignment guides.

methodsDistal femoral cuts using intramedullary alignment rods were simulated by means of a computer-aided engineering software in 4°, 6°, 8°, 10°, and 12° of valgus in relation to the femoral anatomical axis and 4° extension, neutral, as well as 4°, 8°, and 12° of flexion in relation to the femoral mechanical axis. This reflects the different angles between anatomical and mechanical axis in coronal and sagittal planes. To assess the influence of rotation of the alignment guide on the effective distal femoral cutting plane, all combinations were simulated with the rod gradually aligned from 40° of external to 40° of internal rotation.

resultsRotational changes of the distal femoral alignment guides affect both the coronal and sagittal cutting planes. When alignment rods are intruded neutrally with regards to sagittal alignment, external rotation causes flexion, while internal rotation causes extension of the sagittal cutting plane. Simultaneously the coronal effect (valgus) decreases resulting in an increased varus of the cutting plane. However, when alignment rods are intruded in extension or flexion partly contradictory effects are observed. Generally the effect increases with the degree of valgus preset, rotation and flexion.

conclusionAs incorrect rotation of intramedullary alignment guides for distal femoral cuts causes significant cutting errors, exact rotational alignment is crucial. Coronal cutting errors in the distal femoral plane might result in overall leg malalignment, asymmetric extension gaps and subsequent sagittal cutting errors.

Indexed as

RotationArthroplasty, Replacement, KneeComputer-Aided DesignComputer SimulationFemurHumansKnee JointAlignmentDistal cutKneeRodsRotationTKATotal knee arthroplasty

Identifiers

PMID29455244
OpenAlexW2789222142

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.