Evidence map›Paper›PMID 29453623›Full record

ArticleSurgery today2018

A novel suction/coagulation integrated probe for achieving better hemostasis: development and clinical use.

Hidekazu Takahashi, Naotsugu Haraguchi, Junichi Nishimura, Taishi Hata, Chu Matsuda, Hirofumi Yamamoto, Tsunekazu Mizushima, Masaki Mori, Yuichiro Doki, Kiyokazu Nakajima

Abstract read
PubMed Publisher
In one paragraph

Article in Surgery today, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Hidekazu TakahashiDepartment of Gastroenterological Surgery, Osaka University Graduate School of Medicine, 2-2, E-2, Yamadaoka, Suita, Osaka, 565-0871, Japan.
Naotsugu HaraguchiDepartment of Gastroenterological Surgery, Osaka University Graduate School of Medicine, 2-2, E-2, Yamadaoka, Suita, Osaka, 565-0871, Japan.
Junichi NishimuraDepartment of Gastroenterological Surgery, Osaka University Graduate School of Medicine, 2-2, E-2, Yamadaoka, Suita, Osaka, 565-0871, Japan.
Taishi HataDepartment of Gastroenterological Surgery, Osaka University Graduate School of Medicine, 2-2, E-2, Yamadaoka, Suita, Osaka, 565-0871, Japan.
Chu MatsudaDepartment of Gastroenterological Surgery, Osaka University Graduate School of Medicine, 2-2, E-2, Yamadaoka, Suita, Osaka, 565-0871, Japan.
Hirofumi YamamotoDepartment of Gastroenterological Surgery, Osaka University Graduate School of Medicine, 2-2, E-2, Yamadaoka, Suita, Osaka, 565-0871, Japan.
Tsunekazu MizushimaDepartment of Gastroenterological Surgery, Osaka University Graduate School of Medicine, 2-2, E-2, Yamadaoka, Suita, Osaka, 565-0871, Japan.
Masaki MoriDepartment of Gastroenterological Surgery, Osaka University Graduate School of Medicine, 2-2, E-2, Yamadaoka, Suita, Osaka, 565-0871, Japan.
Yuichiro DokiDepartment of Gastroenterological Surgery, Osaka University Graduate School of Medicine, 2-2, E-2, Yamadaoka, Suita, Osaka, 565-0871, Japan.
Kiyokazu NakajimaDepartment of Gastroenterological Surgery, Osaka University Graduate School of Medicine, 2-2, E-2, Yamadaoka, Suita, Osaka, 565-0871, Japan. knakajima@gesurg.med.osaka-u.ac.jp.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposesModern electrosurgical tools have a specific coagulation mode called "soft coagulation". However, soft coagulation has not been widely accepted for surgical operations. To optimize the soft coagulation environment, we developed a novel suction device integrated with an electrosurgical probe, called the "Suction ball coagulator" (SBC). In this study, we aimed to optimize the SBC design with a prototyping process involving a bench test and preclinical study; then, we aimed to demonstrate the feasibility, safety, and potential effectiveness of the SBC for laparoscopic surgery in clinical settings.

methodsSBC prototyping was performed with a bench test. Device optimization was performed in a preclinical study with a domestic swine bleeding model. Then, SBC was tested in a clinical setting during 17 clinical laparoscopic colorectal surgeries.

resultsIn the bench tests, two tip hole sizes and patterns showed a good suction capacity. The preclinical study indicated the best tip shape for accuracy. In clinical use, no device-related adverse event was observed. Moreover, the SBC was feasible for prompt hemostasis and blunt dissections. In addition, SBC could evacuate vapors generated by tissue ablation using electroprobe during laparoscopic surgery.

conclusionsWe successfully developed a novel, integrated suction/coagulation probe for hemostasis and commercialized it.

Indexed as

Equipment DesignAnimalsColorectal SurgeryDisease Models, AnimalElectrocoagulationFeasibility StudiesFemaleHemorrhageHemostasis, EndoscopicHumansLaparoscopySwineDevice developmentHemostasisLaparoscopic surgerySoft coagulation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials