Trial reportJournal of diabetes science and technology2018

Evaluation of a New Noninvasive Glucose Monitoring Device by Means of Standardized Meal Experiments.

Andreas Pfützner, Stephanie Strobl, Filiz Demircik, Lisa Redert, Johannes Pfützner, Anke H Pfützner, Alexander Lier

Abstract readClinical Trial
In one paragraph

Trial report in Journal of diabetes science and technology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed.

  1. Review
  2. Review
  3. Noninvasive Glucose Sensing In Vivo.Sensors (Basel, Switzerland) · 2023
    Review
  4. Article
  5. Review
  6. Review
  7. Review
  8. Review
  9. Article
  10. Article
  11. Review
  12. Article
  13. Review
  14. Improving patient self-care using diabetes technologies.Therapeutic advances in endocrinology and metabolism · 2019
    Review
  15. Article
  16. Device and Method for Noninvasive Glucose Assessment.Journal of diabetes science and technology · 2018
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Andreas Pfützner1 Pfützner Science & Health Institute, Mainz, Germany.ORCID 0000-0003-2385-0887
Stephanie Strobl1 Pfützner Science & Health Institute, Mainz, Germany.
Filiz Demircik1 Pfützner Science & Health Institute, Mainz, Germany.
Lisa Redert3 Technical University, Bingen, Germany.
Johannes Pfützner3 Technical University, Bingen, Germany.
Anke H Pfützner2 Sciema UG, Mainz, Germany.
Alexander Lier1 Pfützner Science & Health Institute, Mainz, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFrequent blood glucose readings are the most cumbersome aspect of diabetes treatment for many patients. The noninvasive TensorTip Combo Glucometer (CoG) component employs dedicated mathematical algorithms to analyze the collected signal and to predict tissue glucose at the fingertip. This study presents the performance of the CoG (the invasive and the noninvasive components) during a standardized meal experiment.

methodsEach of the 36 participants (18 females and males each, age: 49 ± 18 years, 14 healthy subjects, 6 type 1 and 16 type 2 patients) received a device for conducting calibration at home. Thereafter, they ingested a standardized meal. Blood glucose was assessed from capillary blood samples by means of the (non)invasive device, YSI Stat 2300 plus, Contour Next at time points -30, 0, 15, 30, 45, 60, 75, 90, 120, 150, and 180 minutes. Statistical analysis was performed by consensus error grid (CEG) and calculation of mean absolute relative difference (MARD) in comparison to YSI.

resultsFor the noninvasive (NI) CoG technology, 100% of the data pairs were found in CEG zones A (96.6%) and B (3.4%); 100% were seen in zone A for the invasive component and Contour Next. MARD was calculated to be 4.2% for Contour Next, 9.2% for the invasive component, and 14.4% for the NI component.

conclusionsAfter appropriate individual calibration of the NI technology, both the NI and the invasive CoG components reliably tracked tissue and blood glucose values, respectively. This may enable patients with diabetes to monitor their glucose levels frequently, reliably, and most of all pain-free.

Indexed as

MealsAdultAgedBlood GlucoseBlood Glucose Self-MonitoringDiabetes Mellitus, Type 1Diabetes Mellitus, Type 2EatingFemaleHumansMaleMiddle AgedMonitoring, PhysiologicPostprandial PeriodReference StandardsYoung AdultBlood Glucosechaos theorycolor sensor imagingfingertip tissueinvasive device componentnoninvasive glucose prediction

Identifiers

PMID29451016
PMCPMC6232728

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.