ArticleDer Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft2019

[Intraoperative optical coherence tomography in explorative vitrectomy in patients with vitreous haemorrhage-a case series].

D Heinrich, S Bohnacker, M A Nasseri, N Feucht, C P Lohmann, M Maier

Abstract read
PubMed Publisher
In one paragraph

Article in Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.5field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. [Real-time optical coherence tomography-assisted high-precision vitreoretinal surgery in the clinical routine].Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft · 2020
    Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

D HeinrichAugenklinik, Klinikum rechts der Isar, Technische Universität München, Ismaninger Straße 22, 81675, München, Deutschland. dominic.heinrich@mri.tum.de.
S BohnackerAugenklinik, Klinikum rechts der Isar, Technische Universität München, Ismaninger Straße 22, 81675, München, Deutschland.
M A NasseriAugenklinik, Klinikum rechts der Isar, Technische Universität München, Ismaninger Straße 22, 81675, München, Deutschland.
N FeuchtAugenklinik, Klinikum rechts der Isar, Technische Universität München, Ismaninger Straße 22, 81675, München, Deutschland.
C P LohmannAugenklinik, Klinikum rechts der Isar, Technische Universität München, Ismaninger Straße 22, 81675, München, Deutschland.
M MaierAugenklinik, Klinikum rechts der Isar, Technische Universität München, Ismaninger Straße 22, 81675, München, Deutschland.
Klinikum rechts der Isar · DETechnical University of Munich · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHigh-resolution spectral domain optical coherence tomography (SD-OCT) is a gold standard technique for diagnosis, management and monitoring of patients with vitreoretinal diseases. Preoperative diagnostics for evaluation of intraocular and retinal status in patients with vitreous haemorrhage are limited, thus final therapeutic decisions can only be made during explorative vitrectomy. We evaluated the use of intraoperative SD-OCT (iSD-OCT) as a real-time additional diagnostic tool during explorative vitrectomy in patients with vitreous haemorrhage.

methodsWe report on 9 patients (11 eyes) with vitreous haemorrhage. Preoperative ultrasound was performed to evaluate intraocular status. Subsequently, an explorative 23G pars plana vitrectomy was performed under visualisation with the OPMI Lumera 700 surgical microscope (Carl Zeiss Meditec, Jena, Germany) equipped with a fully integrated iSD-OCT device (Rescan 700, Carl Zeiss Meditec, Jena, Germany) as a real-time diagnostic tool.

resultsIn all patients, intraoperative iSD-OCT allowed real-time evaluation of the preretinal, intraretinal and subretinal structures in addition to the intraoperative en face image. The further surgical strategy, i. e. necessity for peeling of epiretinal membranes (ERM) or of the inner limiting membrane (ILM), application of intravitreal medication and selection of the appropriate tamponade, was based on and optimised according to the iSD-OCT images.

conclusionIntraoperative iSD-OCT is highly useful as an additional intraoperative diagnostic tool in patients with vitreous haemorrhage. In addition to the en face microscope image, it facilitates intraoperative real-time diagnosis and aids therapeutic decision-making during surgery.

Indexed as

Epiretinal MembraneVitrectomyGermanyHumansTomography, Optical CoherenceVitreous HemorrhageIntraoperative OCTMacular surgeryOCTVitreoretinal surgeryVitreous haemorrhage

Identifiers