Evidence map›Paper›PMID 29443868›Full record

ArticleSensors (Basel, Switzerland)2018

Circular Array of Magnetic Sensors for Current Measurement: Analysis for Error Caused by Position of Conductor.

Hao Yu, Zheng Qian, Huayi Liu, Jiaqi Qu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Hao YuSchool of Instrumentation Science and Opto-Electronics Engineering, Beihang University, Beijing 100191, China. yuhaoby@buaa.edu.cn.ORCID 0000-0002-4692-3965
Zheng QianSchool of Instrumentation Science and Opto-Electronics Engineering, Beihang University, Beijing 100191, China. qianzheng@buaa.edu.cn.
Huayi LiuSchool of Instrumentation Science and Opto-Electronics Engineering, Beihang University, Beijing 100191, China. liuhy_one@163.com.
Jiaqi QuSchool of Instrumentation Science and Opto-Electronics Engineering, Beihang University, Beijing 100191, China. qujiaqi@buaa.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper analyzes the measurement error, caused by the position of the current-carrying conductor, of a circular array of magnetic sensors for current measurement. The circular array of magnetic sensors is an effective approach for AC or DC non-contact measurement, as it is low-cost, light-weight, has a large linear range, wide bandwidth, and low noise. Especially, it has been claimed that such structure has excellent reduction ability for errors caused by the position of the current-carrying conductor, crosstalk current interference, shape of the conduction cross-section, and the Earth's magnetic field. However, the positions of the current-carrying conductor-including un-centeredness and un-perpendicularity-have not been analyzed in detail until now. In this paper, for the purpose of having minimum measurement error, a theoretical analysis has been proposed based on vector inner and exterior product. In the presented mathematical model of relative error, the un-center offset distance, the un-perpendicular angle, the radius of the circle, and the number of magnetic sensors are expressed in one equation. The comparison of the relative error caused by the position of the current-carrying conductor between four and eight sensors is conducted. Tunnel magnetoresistance (TMR) sensors are used in the experimental prototype to verify the mathematical model. The analysis results can be the reference to design the details of the circular array of magnetic sensors for current measurement in practical situations.

Indexed as

circular arraycurrent measurementtunnel magnetoresistance sensorsun-centerun-perpendicular

Identifiers

PMID29443868
PMCPMC5856180

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.